Asphalt Density Gauge – Non-Nuclear QualiADG™
Measure asphalt density and compaction without the licensing, badges, and transport controls of nuclear gauges. The non-nuclear QualiADG supports ASTM D7113-05 and AASHTO T343-12 work, delivering GPS-tagged density results in seconds through a rugged touchscreen field instrument.
Description
Applications
Features
Specifications
Traditional nuclear density gauges require burdensome regulatory licensing, hazardous transport compliance, and specialized storage safeguards that stall paving projects. The non-nuclear QualiADG™ eliminates these operational liabilities by leveraging advanced electromagnetic technology to deliver safe, rapid asphalt density and compaction profiling on-site.
Engineered for absolute metrological precision, this portable non-destructive testing (NDT) instrument ensures strict compliance with ASTM D7113 and AASHTO T343 standards. It automatically calculates compaction percentages against target Marshall or Rice values while measuring surface temperatures up to 350°C.
Featuring a lightweight 3.0 kg handheld design, the system optimizes field inspection throughput via single, average, and continuous scanning modes. Its integrated GPS module automatically geotags spatial coordinates to raw datasets, enabling seamless, software-free USB data logging and professional compliance reporting.
What the Asphalt Density Gauge Measures
The QualiADG™ is a multi-parameter diagnostic system designed to characterize the physical quality, thermal state, and compaction efficiency of freshly laid asphalt concrete:
- Asphalt Density: Measures the bulk density of the compacted asphalt mixture in real-time, providing immediate data on consolidation.
- Percent Compaction: Automatically calculates the compaction percentage relative to a user-programmable target density (such as the Marshall or Rice density values).
- Porosity Percentage: Determines the percentage of air voids within the compacted material, which is critical for evaluating moisture permeability and long-term durability.
- Surface Temperature: Features integrated infrared temperature sensing to display real-time pavement temperatures from 0 degrees Celsius to 350 degrees Celsius.
- Subsurface Moisture Content: Evaluates moisture-related physical variations within the asphalt layer to detect premature water-entrapment risks.
Why Non-Nuclear Asphalt Testing Matters
Traditionally, verifying asphalt compaction required using nuclear density gauges or taking destructive core samples. While nuclear gauges are highly accurate, they rely on radioactive radium or cesium sources, presenting significant operational, regulatory, and financial challenges:
- Eliminating the Licensing and Compliance Burden: Nuclear gauges require expensive radiation safety training, individual operator badges, specialized storage facilities, and complex transport documentation. The non-nuclear QualiADG™ completely bypasses these regulations, letting teams deploy immediately with no safety compliance overhead.
- Safer and Environmentally Friendly Operations: By removing the radioactive source, the asphalt compaction tester presents zero health risks to site personnel and is entirely environmentally friendly, preventing radiation safety liabilities on active municipal jobsites.
- Exceptional Cost-per-Test Efficiency: Eliminates the long-term fees associated with specialized nuclear transport, regulatory reporting, and hazardous material disposal.
- Immediate, High-Volume Data Capture: While core drilling is slow, destructive, and requires localized patching, the QualiADG™ delivers non-destructive results in just three seconds. This allows technicians to perform hundreds of scans per shift to map out large-scale highway lanes or airport runways seamlessly.
The QualiADG™ is optimized for high-mobility field quality control and compaction verification across several civil engineering sectors:
- Road and Highway Construction: Real-time density monitoring of asphalt base courses, binder courses, and surface wearing layers.
- Foundations and Parking Facilities: Verifying asphalt stability and compaction uniformity for residential, commercial, and industrial parking zones.
- On-Site Compaction Verification: Providing immediate, non-destructive feedback behind the roller compactor to optimize rolling patterns and ensure compliance before the mix cools.
- Field Asphalt Quality Control (QA/QC): Establishing a rapid preliminary screening program for third-party inspectors and municipal engineering auditors.
- Airport Runway and Taxiway Inspections: Verifying strict, high-density specifications on heavy-duty asphalt pavements.
- Urban Utility Trench and Backfill Auditing: Scanning localized asphalt patches and backfills around utility lines and pipeline channels.
- Full-Color Touchscreen User Interface: Large, high-resolution full-color VGA display that supports direct touchscreen input for rapid on-site menu navigation and parameter configuration.
- Microsoft Windows CE Operating System: Driven by a robust embedded operating system, providing a stable software environment with a user-friendly graphical interface.
- No Additional Calibration Required: The advanced internal sensor design delivers stable, repeatable, and precise readings under standard conditions without continuous pre-test calibration.
- Vibrant LED Backlighting: Outfitted with high-visibility backlighting to ensure excellent screen readability under direct, intense outdoor sunlight or during night-shift paving.
- Intelligent Operational Status Bar: The real-time status bar displays current GPS status, data save status, active battery voltage, low battery alerts, date, and time.
- Rugged, Lightweight, and Portable Build: Sized for effortless handheld use and weighing only 3.0 kg, the device minimizes operator fatigue during extensive daily mapping campaigns.
- Flexible Unit Selection: Supports interchangeable units of measurement for density, temperature, depth, and stone size to match regional project specifications.
- On-Board Diagnostic Screen: Features a specialized diagnostic utility screen to assist factory support and calibration teams during routine maintenance.
Data Management, GPS, and Reporting Workflow
The QualiADG™ is designed to function as an intelligent data acquisition and field-reporting node:
- High-Capacity Project and Mix Storage: Stores the specific details of up to 10 independent projects and up to 20 distinct asphalt mixes. Mix profiles include the Maximum Theoretical Density (MTD), mix name, stone size, lift depth, offset, and operator name.
- Integrated GPS Geotagging: Automatically captures and links geographical coordinates—including latitude, longitude, active satellite count, UTC date/time, and Universal Transverse Mercator (UTM) format—to every saved measurement.
- Turnkey USB Export and Reporting: Stored records can be easily exported via a built-in USB port directly to a standard flash memory drive. Data is output in formats compatible with Microsoft Excel, allowing for immediate generation of polished compliance reports.
- One-Touch Software Updates: Keeps the system up to date with one-touch software updates executed directly via a USB memory stick.
- Custom Time and Date Formats: Allows users to configure time and date layouts, supporting MM/DD, D/YY, and DD/MM/YY formats to align with varying administrative requirements.
Operational Modes and Field Use
The QualiADG™ adapts to different jobsite workflows through three distinct operational modes, providing technicians with versatile testing paths:
1. Single Mode
Designed for rapid spot checks, this mode delivers a precise density and compaction reading in less than five seconds and automatically saves the data to the project file.
2. Average Mode
To account for localized aggregate distribution, this mode automatically averages five consecutive readings and stores the combined dataset along with a precise date and time stamp, with memory capacity to store thousands of records.
3. Continuous Mode
Provides instantaneous, real-time density and compaction readings as the operator moves the gauge across the pavement, making it ideal for locating compaction transition boundaries and structural anomalies.
Core Correlation and Offset Calibration
For high-stakes compliance testing, the QualiADG™ features a “Normal Calibration” mode. This allows the operator to input the physical density values from actual core samples. The software automatically calculates a correlation offset, aligning the non-nuclear gauge’s electromagnetic readings with the physical laboratory core results for maximum accuracy on a specific mix design.
Operational Specifications
- Single Mode Reading Time: Less than five (5) seconds (Stores data)
- Average Mode Reading Time: Averages five (5) readings and stores data (Includes date, time, and thousands of records)
- Continuous Mode Reading Time: Instantaneous, real-time density readings
- Measurable Functions: Density, percent Compaction, Porosity percent
- Integrated Temperature Sensing Range: Real-time display from 0 degrees Celsius to 350 degrees Celsius
- Calibration Modes: Normal (Correlation offset to physical cores)
Measurement Specifications
- Sensing Area Footprint: 11 inch (27.9 cm) diameter base
- Maximum Measurement Depth: 110 mm
- Measurement Display Fields: Density, percent Compaction, Surface Temperature, Mix Name, and Project Name
Mechanical Specifications
- Shipping Weight (with Case): 9.00 kg
- Shipping Case Dimensions: 490 x 220 x 390 mm
- Housing Portability: Lightweight handheld design with protective carry case
Electrical Specifications
- Control System: Microprocessor controlled logic
- Battery Configuration: 2.5 Amp-hour NiMH, 12V
- Recharge Time: 4 hours
- Battery Charger: 12V Universal AC charger
- Computer Communication Ports: 1 USB Port
Experience the Qualitest advantage and see how we can elevate your testing and quality control processes.
Please contact us for pricing, check availability, or ask for additional information about: