Coating Thickness Gauge – QualiCTG™ III
Narrow access points and thick coatings can force inspectors to switch tools mid-job. QualiCTG III uses a replaceable external probe for tighter spaces, measures up to 5,000 µm, and sends results by Bluetooth or USB while handling paint, galvanizing, plating, and film checks across metal substrates.
Description
Applications
Features
Specifications
Standard integrated coating gauges fail to access confined geometries or measure ultra-thick protective layers, risking uninspected defects. The QualiCTG™ III Coating Thickness Gauge solves this restriction by separating the main unit from an external, wear-resistant ruby tip probe.
Equipped with a 1000 mm cable, this portable instrument easily maneuvers into tight spaces. It expands inspection versatility by offering interchangeable probes supporting up to 5000 μm on ferrous substrates, eliminating multi-device overhead for heavy industrial claddings.
Operating in full compliance with ISO 2178, ISO 2360, and ASTM D7091 standards, it delivers traceably secure data. A 2.4-inch color screen visualizes real-time curve and trend charts, helping technicians catch application drift instantly during maritime or automotive quality control workflows.
The Coating Thickness Gauge – QualiCTG™ III is engineered for demanding inspection environments requiring high-speed data acquisition and specialized probe access:
- Car Paint Thickness Detection: Performing rapid vehicle audits to identify non-standard paint layers or repairs.
- Ship Manufacturing Inspection: Verifying anti-corrosive coating thickness on hulls, decks, and structural elements.
- Electroplating and Metal Processing: Monitoring the thickness of protective plating on hardware parts and machined components.
- Anti-Rust Treatment Verification: Ensuring that galvanized layers on industrial steel meet strict corrosion-resistance specifications.
- Narrow-Space Inspection: Utilizing the external probe to reach internal surfaces and confined interfaces where integrated gauges cannot operate.
- Film and Cladding Detection: Measuring the uniformity of plastic films and non-conductive claddings on various metallic bases.
- Substrate-Specific Testing: Inspecting iron and stainless steel surfaces (Fe) or aluminum and copper surfaces (NFe) with automatic mode switching.
The QualiCTG™ III integrates advanced AI-supported sensing with professional data visualization tools:
- External Probe Configuration: Features a detachable probe for easier replacement and superior accessibility in restricted or recessed measurement areas.
- Extended Measurement Range: Offers multiple probe options to support thicknesses up to 5000 μm, tailored to specific industrial coating requirements.
- Automatic Substrate Recognition: Intelligently identifies whether the base metal is ferrous or non-ferrous, optimizing the measurement principle instantly.
- Professional Chart Visualization: Displays measurement data as real-time curves, bar charts, or trend charts on a 2.4-inch high-resolution color screen.
- Bluetooth and APP Integration: Transmits measurement results in real-time to a mobile device for advanced documentation and field sharing.
- High-Accuracy Ruby Probe: Equipped with a wear-resistant ruby tip to ensure long-term stability and precise contact across millions of cycles.
- Comprehensive Statistical Engine: Automatically calculates number of readings, max, min, mean, sample standard deviation, and coefficient of variation.
- Intelligent Status Feedback: Features a tri-color LED system (red for alarm, blue/green for status reminders) and a red backlight alert for over-limit results.
- Rapid Measurement Workflow: Capable of executing up to 2 measurements per second, significantly increasing inspection throughput.
- Self-Adaptive Technology: Integrates AI for environmental self-adaptation and self-protection, ensuring reliable performance in varying site conditions.
- User-Focused Interface: Includes automatic screen rotation, brightness adjustment, and a standardized menu system for intuitive navigation.
Fe and NFe Coating Measurement Workflow
The QualiCTG™ III utilizes two established physical principles to evaluate applied layers without sample destruction. For Fe substrates—including iron, nickel, cobalt, and other ferromagnetic metals—the instrument employs magnetic induction. For NFe substrates like aluminum, copper, and zinc, it utilizes eddy current measurement. As the operator applies the external probe to the surface, the instrument identifies the substrate properties automatically. This contact-based system calculates the thickness of the paint, galvanization, or plastic film as the mechanical trigger is engaged, providing immediate feedback on the color display.
Probe Options and Measurement Range
To accommodate varied industrial specifications, the QualiCTG™ III is compatible with several external probe configurations:
- FN2.0 Probe: Optimized for standard applications with a range of 0 to 2000 μm.
- FN3.0 Probe: Designed for thicker protective layers with a range of 0 to 3000 μm.
- F5.0N3.0 Probe: A high-capacity option supporting up to 5000 μm on Fe substrates and 3000 μm on NFe substrates.
The probes are constructed from durable stainless steel and feature a specialized 1000 mm cable for extended reach. The mechanical trigger mode ensures a consistent force of 0.4 to 0.8 N is applied, maintaining data repeatability while protecting the measured surface.
Data Analysis, Charts, Bluetooth, and USB Workflow
Modern quality management is facilitated through the unit’s advanced data handling capabilities. Operators can switch between a “Car Mode” for rapid panel audits and a “General Mode” for broad industrial analysis. The internal memory records data automatically, which can then be visualized through onboard curve or bar charts to identify process drift. For permanent archiving, results can be sent to the mobile APP via Bluetooth or exported to a PC via the USB interface. The system tracks not only the raw thickness values but also calculates the number of readings above or below user-defined limits to streamline compliance reporting.
Calibration, Substrate Requirements, and Operating Conditions
Consistent accuracy is maintained through user-friendly zero-point and multi-point calibration procedures. The QualiCTG™ III is designed to operate on a wide variety of part shapes, requiring a minimum diameter of 15 mm for the measurement area and adhering to specific curvature limits (convex: 5 mm / concave: 25 mm). Substrate thickness limits are strictly defined at 0.20 mm for Fe and 0.03 mm for NFe to ensure sensing integrity. Built with an IP40 protection class, the unit functions reliably in temperatures ranging from -10 to +50°C, making it suitable for both controlled metrology rooms and outdoor manufacturing sites.
Measurement System
| Feature | Specification |
| Model | Coating Thickness Gauge – QualiCTG™ III |
| Measuring Principle | Fe: Magnetic Induction / NFe: Eddy Current |
| Measurement Ranges | FN2.0: 0-2000 μm; FN3.0: 0-3000 μm; F5.0N3.0: 5000/3000 μm |
| Accuracy (FN2.0) | ±(2% reading + 1 μm) |
| Resolution Ratio | 0.1 μm (0-99.9 μm); 1 μm (≥100 μm) |
| Measuring Units | μm, mm, mil, inch |
| Measurement Speed | 2 readings per second |
Calibration, Statistics, and Storage
| Feature | Specification |
| Calibration Methods | Zero Calibration, Multi-point Calibration |
| Statistical Metrics | Count, Max, Min, Mean, Std. Dev, CV, Over/Under limits |
| Graphical Display | Curve chart, Bar chart, Trend chart |
| Data Storage | 10 × 13 × 10 measurement data groups |
| Status Alerts | Red LED (Alarm); Blue/Green LED (Status); Red Backlight |
Probe and Substrate Requirements
| Feature | Specification |
| Probe Design | External with 1000 mm cable |
| Probe Material | Stainless Steel with Ruby Tip |
| Trigger Force | 0.4 to 0.8 N (Mechanical trigger) |
| Min. Substrate (Fe / NFe) | 0.20 mm / 0.03 mm |
| Min. Radius (Convex/Concave) | 5 mm / 25 mm |
| Min. Measuring Area | Diameter 15 mm |
Connectivity, Power, and Physical
| Feature | Specification |
| Display | 2.4-inch color screen with auto-rotation |
| Connectivity | Bluetooth (Mobile App) / USB (PC connection) |
| Protection Class | IP40 |
| Battery Type | 2x AA (Alkaline or Ni-MH) |
| Housing Material | ABS |
| Dimensions (Housing) | 146 × 76 × 32 mm |
| Weight (Housing / Probe) | 137 g / ~63 g |
Experience the Qualitest advantage and see how we can elevate your testing and quality control processes.
Please contact us for pricing, check availability, or ask for additional information about: