Macro Vickers Hardness Tester QualiVick™ 10/30/50 Auto – Fully Automatic Series
Eliminate eyepiece strain and manual mapping errors with the QualiVick™ 10/30/50 Auto Series Macro Vickers Tester. Meeting ASTM E92 and ISO 6507, it combines CCD imaging, a motorized X-Y table, and automatic focusing to automate hardness profiling across multiple test points.
Manual eyepiece readings in high-volume macro Vickers testing cause massive operator eye strain and inconsistent results across technicians. The QualiVick™ Auto Series solves this operational bottleneck by fully automating stage movement, focusing, loading, and measurement within a single hands-free platform.
Equipped with a 1.3-megapixel CCD camera and a motorized X-Y test table, this digital system delivers automated multi-point hardness mapping. Driven by an onboard Intel i5 computer, it eliminates human interpretation errors to secure absolute repeatability on complex industrial cross-sections.
Operating in absolute compliance with ASTM E92 and ISO 6507 standards, the series automatically generates critical hardness-depth curves. Available in 10, 30, and 50 kgf capacities, it provides project-ready Word or Excel reports to accelerate demanding metallurgical quality control.
The QualiVick™ 10/30/50 Auto Series provides advanced analysis for a wide variety of materials and surface treatments:
- Ferrous & Non-Ferrous Metals: Standardized hardness verification for structural and automotive alloys.
- Surface Engineering: Precise profiling of carbonized layers and quench-hardened layers.
- Delicate Components: Evaluating IC thin sections and composite ply-metals with high positional accuracy.
- Brittle & Hard Materials: Macro-scale analysis of glass, ceramics, agate, and precious stones.
- Hardness Mapping: Executing automated depth and trapezium hardness testing across cross-sections.
- Advanced Coatings: Testing thin plastic sections and specialized surface coatings for industrial durability.
The QualiVick™ Auto Series transforms the laboratory experience through a seamless, fully automatic digital workflow:
- Total Automation: Integrates automatic loading, dwelling, unloading, stage movement, focusing, and measurement into a single hands-free process.
- Integrated Computing Power: Built with an onboard panel computer running Windows 7, offering a direct touch-screen interface for parameter selection and image analysis.
- Motorized X-Y Precision: Features a motorized test table with 50 x 50 mm travel, allowing for automated multi-point testing and coordinate-based mapping.
- Automatic Focusing & Measuring: The CCD acquisition system automatically focuses the image and retrieves the hardness value, removing subjective manual errors and visual strain.
- Intelligent Turret System: Supports automatic recognition and high-speed shifting between the three objectives and the diamond indenter.
- Enhanced Connectivity: Includes USB, VGA, and LAN interfaces for seamless network integration, external monitor support, and peripheral connectivity.
- Advanced Reporting: Automatically generates hardness-depth curves and exports comprehensive data directly to WORD or EXCEL formats.
Why This Fully Automatic Series Matters
The transition to a fully automatic system is critical for laboratories managing high test volumes or complex multi-point measurements. By eliminating the manual eyepiece-based measurement workflow, the QualiVick™ Auto Series drastically reduces operator fatigue and the potential for inconsistent results between different technicians. This unified platform combines testing, stage movement, focusing, and reporting, allowing for a “set and forget” workflow that frees up laboratory personnel for other tasks while ensuring that every indentation strictly adheres to international standards.
Automation, Imaging, and Data Workflow
The QualiVick™ Auto workflow is defined by its digital-first approach. Operators select test parameters and coordinate patterns via the external touch screen. The system then takes over, moving the motorized stage to precise locations, performing the indentation cycle, and using the 1.3-megapixel CCD camera to acquire and measure the image. With integrated Intel i5 processing and 8GB of RAM, the system handles complex image processing and data logging in real-time. Results are saved automatically, allowing for the immediate creation of detailed hardness-depth profiles and professional reports that can be printed or shared over the local network.
Model Comparison
The series offers three variants to match your specific force-range requirements:
- QualiVick™ 10 Auto: Optimized for lower macro-forces, with a range from 0.2 kgf to 10 kgf.
- QualiVick™ 30 Auto: A versatile mid-range solution covering 0.3 kgf up to 30 kgf.
- QualiVick™ 50 Auto: The high-capacity model designed for heavy-duty testing up to 50 kgf.
All “Auto” models share the same motorized stage, auto-focus software, and high-performance computing hardware.
Standards and Compliance
The QualiVick™ 10/30/50 Auto Series is fully compliant with the following standards:
- ISO 6507
- ASTM E92
- JIS Z2244
- GB/T 4340.2
Standard Configuration
- Main Body (Integrated Hardware)
- External Touch Screen
- 10× Eyepiece
- 10×, 20×, and 40× Objectives
- Diamond Vickers Indenter
- Motorized X-Y Test Table
- Hardness Block (700~800 HV1)
- Hardness Block (400~500 HV5)
- Halogen Lamp (12V, 20W)
- Optical Mouse
- Warranty Documentation
| Category | QualiVick™ 10 Auto | QualiVick™ 30 Auto | QualiVick™ 50 Auto |
| Test Force (kgf) | 0.2, 0.3, 0.5, 1, 2, 2.5, 3, 5, 10 | 0.3, 0.5, 1, 2, 2.5, 3, 5, 10, 20, 30 | 0.5, 1, 2, 2.5, 3, 5, 10, 20, 30, 50 |
| Test Force (N) | 1.96, 2.94, 4.90, 9.80, 19.6, 24.5, 29.4, 49, 98 | 2.94, 4.90, 9.80, 19.6, 24.5, 29.4, 49, 98, 196, 294 | 4.90, 9.80, 19.6, 24.5, 29.4, 49, 98, 196, 294, 490 |
| Micro Computer | Intel I5, 8G RAM, 240G SSD | Intel I5, 8G RAM, 240G SSD | Intel I5, 8G RAM, 240G SSD |
| CCD Pixel | 1.30 Million Pixels | 1.30 Million Pixels | 1.30 Million Pixels |
| Loading Method | Automatic (Load/Dwell/Unload) | Automatic (Load/Dwell/Unload) | Automatic (Load/Dwell/Unload) |
| Turret Type | Automatic Shifting | Automatic Shifting | Automatic Shifting |
| Conversion Scales | HV, HK, HRA, HRBW, HRC, HRD, HR15N, HR30N, HR45N, HS, HBW | HV, HK, HRA, HRBW, HRC, HRD, HR15N, HR30N, HR45N, HS, HBW | HV, HK, HRA, HRBW, HRC, HRD, HR15N, HR30N, HR45N, HS, HBW |
| Min. Measure Unit | 0.1μm (10×), 0.05μm (20×), 0.025μm (40×) | 0.1μm (10×), 0.05μm (20×), 0.025μm (40×) | 0.1μm (10×), 0.05μm (20×), 0.025μm (40×) |
| Motorized X-Y Table | 110 x 110 mm (Travel: 50 x 50 mm) | 110 x 110 mm (Travel: 50 x 50 mm) | 110 x 110 mm (Travel: 50 x 50 mm) |
| Max. Sample Height | 170 mm | 170 mm | 170 mm |
| Throat Depth | 130 mm | 130 mm | 130 mm |
| Weight (Net/Gross) | 52 kg / 67 kg | 52 kg / 67 kg | 52 kg / 67 kg |
| Dimensions | 560 × 335 × 675 mm | 560 × 335 × 675 mm | 560 × 335 × 675 mm |
Experience the Qualitest advantage and see how we can elevate your testing and quality control processes.
Please contact us for pricing, check availability, or ask for additional information about: