Micro-Wave-Scan 3 Orange Peel DOI Meter
Micro-Wave-Scan 3 is designed for curved and small painted parts where larger appearance meters are awkward. It measures orange peel and DOI on bumpers and mirror housings, supports sample sizes as small as 25 x 40 mm, and feeds Smart-Chart with pass/fail data for tighter paint control.
Description
Applications
Features
Specifications
The Micro-Wave-Scan 3 Orange Peel DOI Meter measures orange peel, Distinctness of Image (DOI), and surface waviness on small and curved high-gloss parts. Its compact housing fits comfortably in one hand and supports surfaces with a curvature radius greater than 300 mm.
Selectable 5, 10, and 20 cm scan lengths accommodate different component geometries. DOI, du, Wa, and Wb can also be measured without scanning through the 0 cm mode. The minimum sample size is only 25 x 40 mm.
A large capacitive color touchscreen provides measurement setup, stored-data review, and direct Pass/Fail evaluation. Smart-Chart software extends the workflow with standards management, SPC analysis, SQL-based data storage, reporting, and standardized sampling procedures.
The Micro-Wave-Scan 3 supports appearance measurement where limited surface area or component curvature makes larger instruments less practical:
- Small Part Appearance Measurement: Evaluates orange peel and DOI on compact finished components with a minimum sample size of 25 x 40 mm.
- Curved Surface Inspection: Measures parts with a curvature radius greater than 300 mm.
- Bumper Surface Evaluation: Quantifies appearance on curved automotive exterior components.
- Mirror Housing Inspection: Supports controlled measurement on smaller painted housings and trim parts.
- Door Handle and Decorative Trim Testing: Evaluates localized high-gloss surfaces with limited measurement area.
- Gas Tank Door Inspection: Measures orange peel and DOI on small exterior panels.
- Motorcycle Component Evaluation: Supports appearance comparison across compact painted and coated components.
- Production QC: Provides stored measurements, predefined standards, statistics, limits, and direct Pass/Fail results.
- Appearance Development: Analyzes wavelength structures and dominant waviness when evaluating material or process changes.
- Compact Measurement Design: The 0.32 kg handheld instrument is optimized for one-handed use on small and curved parts.
- Small Sample Capability: Requires a minimum sample size of only 25 x 40 mm.
- Curved Surface Support: Measures surfaces with a radius greater than 300 mm.
- Multiple Scan Lengths: Provides 20 cm, 10 cm, 5 cm, and 0 cm measurement modes.
- Non-Scanning DOI Measurement: The 0 cm mode measures du, Wa, Wb, and DOI without moving the instrument across the surface.
- Structure Spectrum Analysis: Evaluates du, Wa, Wb, Wc, and Wd wavelength ranges from below 0.1 mm to 10 mm.
- 375 Points/cm Resolution: Captures detailed optical profile data throughout each scan.
- Direct Pass/Fail Results: Displays acceptance results when corresponding standards and limits are configured.
- Capacitive Color Touchscreen: Supports icon navigation, swipe operation, haptic feedback, and automatic display rotation.
- Onboard Data Storage: Stores up to 10,000 readings within 1,000 test series.
- Optional WiFi Connectivity: Supports automatic wireless data transfer when configured.
- Smart Docking Station: Charges the instrument and supports data transfer while maintaining a second charged battery.
- Smart-Chart Integration: Provides standards management, SPC analysis, database filtering, reporting, and historical trend review.
- Company-Specific Scales: Supports appearance scales and limits tailored to defined quality requirements.
Measurement of Small and Curved Surfaces
Compact geometry distinguishes the Micro-Wave-Scan 3 from larger appearance measurement instruments. Its sensor arrangement supports parts with a radius greater than 300 mm. The measurement area is 4 mm multiplied by the selected scan length.
A minimum sample size of 25 x 40 mm allows measurements on localized areas. Typical applications include mirror housings, fuel doors, door handles, decorative trim, bumpers, and motorcycle components.
Operators can select 20 cm, 10 cm, or 5 cm scans according to available surface area. A 0 cm mode provides du, Wa, Wb, and DOI values without requiring a surface scan.
Orange Peel, DOI, and Structure Spectrum
Surface appearance depends on the size and visibility of waviness observed at different viewing distances. The Micro-Wave-Scan 3 uses a laser source to scan the optical profile of high-gloss surfaces. The resulting profile is separated into defined wavelength ranges.
A camera captures the reflected image to evaluate structures below 0.1 mm. These fine structures contribute to Distinctness of Image and dullness evaluation.
The measurement approach produces a structure spectrum that represents surface characteristics across several spatial ranges. These values provide the basis for orange peel, DOI, and customized appearance scales.
Structure Spectrum
- du: < 0.1 mm
- Wa: 0.1 to 0.3 mm
- Wb: 0.3 to 1 mm
- Wc: 1 to 3 mm
- Wd: 3 to 10 mm
The system measures these structures at a resolution of 375 points/cm. Different scan lengths provide flexibility when the available measurement area changes between components.
Quick Check, Measure, and Pass/Fail Workflow
The color touchscreen organizes measurement functions through an icon-based interface. Capacitive technology supports swipe operation and haptic feedback. Automatic display rotation keeps information oriented during different handling positions.
Quick Check performs an immediate measurement without saving the result. Measure stores readings using predefined scales, statistics, and limits. Data View provides access to previously stored measurements.
Organizer guides operators through predefined sampling procedures using established colors and limits. Configuration allows Quick Check and Measure settings to be adjusted for specific workflows.
When standards and limits are defined through Smart-Chart, the instrument can display Pass/Fail results directly after measurement. Operators can therefore review acceptance status without transferring every reading to a separate computer first.
Company-Specific Appearance Scales
Different manufacturers can evaluate Class A surface appearance using their own target values and scales. The Micro-Wave-Scan 3 supports company-specific appearance scales alongside its measured structure spectrum.
These scales can translate objective surface data into quality criteria aligned with an established appearance evaluation method. Corresponding limits can then be incorporated into standardized QC procedures.
Smart-Chart manages scales, standards, and Pass/Fail limits centrally. This provides a consistent measurement framework when the same appearance requirements need to be applied across different operators or locations.
Dominant Wavelength and Amplitude Analysis
The Micro-Wave-Scan 3 also supports analysis of dominant surface waviness. The measurement method uses Fast Fourier Transformation to filter the optical profile and identify dominant wavelength sizes and their corresponding intensity.
The source methodology was developed in collaboration with VW/Audi. Dominant wavelength information provides another way to characterize visible surface structures beyond conventional waviness scales.
Quality and engineering teams can use this information when comparing material or process changes with measured appearance results. It provides additional context when investigating which surface structures contribute most strongly to observed appearance differences.
Docking Station and Battery Operation
Optimized optical and electronic components support up to 1,000 readings from the rechargeable Li-Ion battery pack, depending on usage. The docking station provides a fixed location for charging and data transfer.
A second rechargeable battery can remain in the docking station while the instrument is in use. LED indicators show battery status so operators can monitor charging availability.
USB provides the standard data-transfer connection. Optional WiFi can be enabled for automatic wireless transfer when required.
Smart-Chart Data Analysis and QC Management
Smart-Chart supports statistical process control and centralized management of appearance measurement data. Standards can define measurement scales, limits, and Pass/Fail criteria for different products or processes.
Organizers establish standardized sampling procedures and guide operators through measurement sequences using custom schematics. Stored results are maintained within an SQL database for long-term data handling.
Database filters can isolate measurements by criteria such as color, time period, or failed test series. The Drill-In function displays the previous 20 measurements for matching model, color, and painting-line combinations.
Custom report layouts can be created for documentation and review. Mini databases can also be extracted and exchanged between participating locations or supply-chain partners using compatible datasets.
Product and Application
| Item | Specification |
| Catalog Number | 7420 |
| Product | Micro-Wave-Scan 3 Orange Peel DOI Meter |
| Application | High-gloss surfaces, du < 40, linear range |
| Object Curvature | Radius > 300 mm |
| Minimum Sample Size | 25 mm x 40 mm |
| Measurement Area | 4 mm x scan length |
| Resolution | 375 points/cm |
Scan Length
| Mode | Measured Parameters |
| 20 cm | du, Wa to Wd, LW, SW, DOI |
| 10 cm | du, Wa to Wd, LW, SW, DOI |
| 5 cm | du, Wa to Wd, LW, SW, DOI |
| 0 cm | du, Wa, Wb, DOI |
Structure Spectrum
| Parameter | Wavelength Range |
| du | < 0.1 mm |
| Wa | 0.1 to 0.3 mm |
| Wb | 0.3 to 1 mm |
| Wc | 1 to 3 mm |
| Wd | 3 to 10 mm |
Measurement Performance
| Item | Specification |
| Repeatability (Std. Dev.) | 8% or > 0.8 |
| Reproducibility (Std. Dev.) | 12% or > 1.2 |
Optical System
| Item | Specification |
| Light Source | Laser diode, LED |
| Laser Energy | < 1 mW |
| Laser Classification | Laser Class 2 |
Memory, Interface, and Languages
| Item | Specification |
| Memory | 10,000 readings in 1,000 test series |
| Interface | USB port, optional WiFi |
| Languages | German, English, Spanish, French, Italian, Japanese, Russian, Chinese |
Power and Physical Specifications
| Item | Specification |
| Power Supply | Rechargeable Li-Ion battery pack |
| Battery Capacity | Up to 1,000 readings depending on usage |
| Weight | 0.32 kg / 0.7 lb |
| Operating Temperature | 0 to 40 °C |
| Storage Temperature | 0 to 60 °C / 32 to 140 °F |
| Relative Humidity | Up to 85% at 35 °C / 95 °F, non-condensing |
| Dimensions (L x W x H) | 8.4 x 4.4 x 11.5 cm / 3.3 x 1.7 x 4.5 in |
Delivery Content
The supplied configuration includes:
- Micro-Wave-Scan 3 instrument
- Checking Tile, catalog number 4829
- Docking Station with USB Cable, catalog number 4857
- Smart-Process Software, two download licenses, catalog number 4831
- Two rechargeable battery packs, catalog number 4827
- Battery holder for AA batteries
- Two batteries
- Certificate
- Manual
- Carrying case and belt case
- 1-day training
System Requirements
| Item | Requirement |
| Operating System | Windows 10 version 1607 or later |
| Processor | Intel i5 2.5 GHz or equivalent; i9 recommended |
| Architecture | x86 and x64 only |
| Memory | 16 GB RAM; 32 GB recommended |
| Free Disk Capacity | 4 GB during installation |
| Monitor Resolution | 1920 x 1080 pixels; 4K recommended |
| Interface | Free USB port |
Experience the Qualitest advantage and see how we can elevate your testing and quality control processes.
Please contact us for pricing, check availability, or ask for additional information about: