Home / Products / Other Portable Testers / Pulse Velocity Tester – Vikasonic
Pulse Velocity Tester – Vikasonic

Pulse Velocity Tester – Vikasonic

Track mortar and concrete setting continuously instead of relying only on subjective penetration checks. Vikasonic logs ultrasonic transition time and damping at high frequency, stores more than 300,000 data points, and also supports pulse velocity, damage assessment, and freeze-thaw research.

Description

Applications

Specifications

Traditional penetrometer and Vicat needle tests rely on subjective manual penetration that disturbs curing matrices and skews setting-time data. The portable Vikasonic solves this by utilizing non-destructive ultrasonic pulse velocity to automate setting behavior and elastic modulus tracking without material disturbance.

Engineered for absolute technical accuracy, this advanced NDT instrument guarantees strict compliance with ASTM C597-16, EN 12504-4:2021, and BS 1881-203 standards. By monitoring stress wave transit times, it eliminates operator bias and slashes standard test deviation to just 18%.

Equipped with a standalone data logger storing 300,000 points and paired 54 kHz or 80 kHz transducers, the system maximizes laboratory throughput. It continuously tracks temperature, signal attenuation, and dynamic Young’s modulus to isolate internal degradation during critical freeze-thaw or curing cycles.

What the Pulse Velocity Tester Measures

The Vikasonic utilizes non-destructive ultrasonic propagation to map the physical transformation and structural integrity of cementitious mixtures:

  • Ultrasonic Transition Time: Measures the precise time required for an ultrasonic pulse to travel through the specimen, with a measurement range from 2 microseconds to 24000 microseconds.
  • Ultrasonic Pulse Velocity: Calculates the wave velocity (in meters per second) through the material, which directly correlates to material density and elasticity.
  • Dynamic Young’s Modulus: Determines the dynamic elastic modulus (expressed in GPa) based on the measured wave velocity and user-entered density parameters.
  • Signal Strength and Damping: Tracks the attenuation of the acoustic wave (measured in decibels), indicating internal structural friction, micro-cracking, or air voids.
  • Specimen Temperature: Continuously logs the internal or surface temperature of the sample during the curing process using an integrated Type K thermocouple.
  • Setting-Time Milestones: Tracks the transition of fresh mortar or concrete from a fluid paste to a load-bearing solid state.
  • Internal Damage Propagation: Monitors the structural degradation of hardened concrete elements subjected to mechanical fatigue or environmental weathering.

How the Ultrasonic Measurement Principle Works

The Vikasonic operates on the physical principle that acoustic wave velocity is directly proportional to the stiffness, density, and mechanical continuity of the medium through which it travels:

  1. Fresh Specimen Placement: To measure setting times, fresh mortar or concrete is placed inside a standardized test cell between a paired transmitter and receiver transducer.
  2. High-Frequency Pulse Emission: The transmitter emits ultrasonic pulses at highly controlled, rapid intervals of 0.25 seconds or less, sending stress waves through the material.
  3. Phase-Change Tracking: During the initial fluid phase, the acoustic wave travels slowly because the unbound particles dissipate much of the energy, resulting in a long transition time and high signal damping.
  4. Structural Consolidation: As the binder sets and hydration products form a cohesive, load-bearing matrix, the physical stiffness of the material rises rapidly. Consequently, the ultrasonic transition time drops sharply, and the sound speed increases.
  5. Continuous Data Logging: The system continuously captures the transition time, wave speed, dynamic Young’s modulus, and signal damping, building a complete, high-resolution digital profile of the material’s structural development.

Why Ultrasonic Setting-Time Measurement Matters

Traditionally, the setting behavior of cementitious materials is determined using penetrometers or Vicat needle apparatuses. While these mechanical methods are widely accepted, they present significant operational and accuracy limitations that the Vikasonic successfully resolves:

  • Eliminating Subjective Operator Bias: Penetration tests require manual intervention, visual reading, and periodic physical penetration of the sample, which introduces human error and disturbs the curing matrix. The Vikasonic provides a fully automated, continuous, and non-contact alternative.
  • Superior Statistical Repeatability: Comparative research shows that traditional Vicat measurements can exhibit a high standard deviation ranging from 27 percent to 40 percent. In contrast, the ultrasonic pulse velocity method dramatically reduces this variation to just 18 percent, ensuring much higher statistical confidence.
  • Drastically Reduced Personnel Costs: Once the test cell is filled and the test is initiated on the Vikasonic, the system runs autonomously without supervision. This allows laboratory technicians to focus on other tasks during long-duration curing cycles.
  • Direct Correlation via Calibration: Because each concrete and mortar mix design has unique chemical and aggregate characteristics, a preliminary calibration between the Vicat and ultrasonic methods is performed for each specific formulation. Once calibrated, the non-destructive ultrasonic method can reliably substitute for manual penetration tests.

The Vikasonic is optimized for versatile, high-resolution diagnostics in both controlled laboratories and rugged field environments:

  • Setting-Time Measurement of Mortar and Fresh Concrete: Monitoring early-age hydration curves and identifying initial and final set thresholds.
  • Laboratory Monitoring of Material Development: Tracking the curing kinetics and strength build-up of innovative, low-carbon, or highly additive-modified concrete formulations.
  • On-Site Structural Damage Assessment: Evaluating concrete elements on active bridges, buildings, and transport networks to assess fire damage or physical overloading.
  • Internal Damage Detection: Identifying hidden voids, honeycombing, cracks, and delaminations within hardened concrete members.
  • Freeze-Thaw Resistance Testing: Conducting non-destructive assessments of specimen degradation during environmental thermal cycles.
  • CIF Test-Related Evaluation: Supporting specialized Capillary Suction, Internal Damage, and Freeze-Thaw (CIF) testing protocols.
  • Direct and Indirect Coupling Tests: Analyzing specimens using direct transducer contact (with coupling gel) or within a specialized water bath.

Measurement Setup and Data Logging

The Vikasonic is designed to function as an independent, high-capacity data acquisition station in the field or laboratory:

  • Preassembled Test Cell Configuration: The standard setting-time test cell contains a fixed holder for the transmitter and receiver pair, enclosing a standard Vicat ring (diameter 70/80 x 40 mm, volume 177 ml) to ensure perfect coaxial transducer alignment.
  • Standalone Operation: The instrument works completely independently without requiring an active PC connection during the test, protecting the system from computer crashes or power losses during long-duration runs.
  • Intuitive Single-Wheel Operation: Features an ergonomic, dust-resistant selection wheel that allows technicians to navigate menus and configure parameters easily, even while wearing heavy-duty laboratory work gloves.
  • Integrated Temperature Tracking: Incorporates a dedicated Type K thermocouple port to log specimen temperature simultaneously with the acoustic properties.
  • Massive Data Logging Capacity: The built-in memory can store over 300,000 data points per dataset. Stored records include the date, time, transit time, pulse velocity, dynamic Young’s modulus, received signal strength, and temperature.
  • Turnkey USB Export: Includes a USB host interface for rapid data transfer. The kit is supplied with two USB flash drives, allowing operators to export datasets directly into Microsoft Excel or customized proprietary analysis software.

Internal Damage and Freeze-Thaw Testing Value

Beyond measuring early-stage fresh mortar setting times, the Vikasonic is an exceptional tool for evaluating long-term durability in hardened concrete:

  • Hardened Specimen Diagnostic Support: By measuring changes in Young’s modulus and acoustic velocity over time, the system quantifies the progression of internal micro-cracking before visible surface spalling occurs.
  • Recommended 54 kHz Transducers: For hardened concrete and larger aggregate structures, we recommend utilizing our 54 kHz transducers. Their lower frequency provides deeper penetration and reduces scattering from internal boundaries, ensuring reliable data through thick elements.
  • Direct Coupling Gel Method: For standard on-site structural checks, the transducers are coupled directly to opposite concrete faces using a specialized, water-soluble coupling gel.
  • Water Bath Coupling Setup: For automated freeze-thaw testing in laboratory chambers, the specimens are submerged in a water bath with two 80 kHz transducers positioned on opposite sides. This liquid-coupled configuration ensures perfectly uniform acoustic transmission across repeated freeze-thaw cycles, providing highly stable, repeatable, and non-invasive damage tracking.

Standards and Compliance

The Vikasonic is engineered, calibrated, and manufactured to ensure complete alignment with recognized international concrete and materials testing standards:

  • ASTM C 597-16: Standard Test Method for Pulse Velocity Through Concrete.
  • EN 12504-4:2021: Testing concrete in structures – Part 4: Determination of ultrasonic pulse velocity.
  • BS 1881: Part 203: Testing concrete – Recommendations for measurement of velocity of ultrasonic pulses in concrete.
  • NF P 98-231-5: Test relating to pavements – Hydrocarbon mixtures – Part 231-5: High-temperature behavior.
  • CEN/TS 12390-9: Testing hardened concrete – Part 9: Freeze-thaw resistance (Slab test methods).
  • CEN/TR 15177: Testing the freeze-thaw resistance of concrete – Internal structural damage.

Measurement Performance

ParameterSpecification
Transit Time Measurement Range2 microseconds to 24000 microseconds (Auto-ranging)
Wavelength Wavelength Accuracyplus or minus 0.1 microseconds
Transducer Frequency Options54 kHz or 80 kHz standard (Others available upon request)
Input SensitivityBetter than 250 microvolts (250 uV)
System Bandwidth (-3dB)10 kHz to 1 MHz
Transmitter Excitation Voltages200V, 750V, 1000V, and 1500Vp
Excitation Pulse WidthLess than or equal to 1 microsecond (1 us)
Selectable Pulse Rates0.1 to 10 seconds
Received Signal Strength0.1 to 20 dB
Over-Range IndicationDisplayed clearly on the screen

Calculated Data

ParameterSpecification
Calculated ParametersPulse velocity (meters per second) and Young’s Modulus (GPa)
Required Input ValuesSpecimen density (kg/m³) and physical sound path length (mm)

Power, Display, and Interface

ParameterSpecification
Power Supply ModeAC Mains or internal battery
Voltage Requirements110V to 240V AC, 50/60 Hz
Battery ConfigurationThree standard AA cells
Display PanelHigh-contrast Liquid Crystal Display (56 mm x 38 mm)
USB InterfaceHost interface for direct USB flash drive connection (2 drives included)
Integrated Real-Time ClockYes (Built-in)
Temperature Sensor PortType K thermocouple interface
Recorded Parameters per PointDate, time, transit time, pulse velocity, Young’s modulus, signal power, and temperature

Test Cell and Ordering Information

ParameterSpecification
Test Cell ConfigurationSpecialized holder for secure transmitter and receiver alignment
Test Ring StandardStandard Vicat Ring as described in ASTM C472-99 or EN 196-3
Vicat Ring DimensionsDiameter 70/80 mm x 40 mm height
Vicat Ring Volume177 ml
Primary Order CodeQualitest-Schleibinger Vikasonic with test cell, transducers, and thermocouple, U0001

Experience the Qualitest advantage and see how we can elevate your testing and quality control processes.

Please contact us for pricing, check availability, or ask for additional information about:

Pulse Velocity Tester – Vikasonic