Home / Products / Other Portable Testers / Concrete NDT Testing Equipment / Rebar Locator & Corrosion Tester QualiRLCT™ 50B
Rebar Locator & Corrosion Tester QualiRLCT™ 50B

Rebar Locator & Corrosion Tester QualiRLCT™ 50B

QualiRLCT 50B combines rebar locating and half-cell corrosion testing so crews can map reinforcement before drilling and assess deterioration with one portable unit. It measures cover depth, estimates bar size, scans spacing and distribution, and records corrosion potential on concrete structures.

Description

Applications

Features

Specifications

Drilling or coring blindly into reinforced concrete risks hitting structural steel mesh, causing immediate tool damage and compromising load-bearing members. The QualiRLCT™ 50B Rebar Locator & Corrosion Tester solves this dangerous field hazard, combining electromagnetic induction scanning and half-cell potential mapping into a single, portable non-destructive testing (NDT) solution.

Equipped with a high-sensitivity electromagnetic sensor, the instrument identifies reinforcing bar positions, estimates nominal diameters from 6 to 50 mm, and maps concrete cover thickness across a dual-range spectrum up to 180 mm. To track degradation trends before visible cracking or spalling occurs, its chemical health module maps active corrosion paths up to 1000 mV across a fully customizable grid array.

Optimized for high-frequency field surveys on bridge decks, highways, tunnels, and building foundations, the QualiRLCT™ 50B features a low-interference shielded design that ensures extreme reading stability in complex construction zones. Powered by standard cells providing over 30 hours of continuous active runtime, it delivers real-time grid and line scanning metrics to streamline structural compliance handovers and maximize rehabilitation budgets.

What the Rebar Locator & Corrosion Tester Measures

The QualiRLCT™ 50B is a high-precision diagnostic system capable of measuring multiple critical variables within reinforced concrete:

  • Reinforcing Bar Detection: Locates the exact position of steel reinforcement grids embedded within the concrete matrix.
  • Concrete Cover Thickness: Measures the distance from the concrete surface to the outermost reinforcing bar (rebar depth measurement) to ensure compliance with structural and fire-rating designs.
  • Rebar Diameter Identification: Automatically estimates the nominal size/diameter of the scanned rebar without having to break the concrete.
  • Rebar Spacing and Distribution: Maps the reinforcement spacing and spatial layout of the steel mesh, identifying areas of irregular distribution or structural deviations.
  • Active Corrosion Potential: Evaluates the probability of active rebar corrosion by measuring half-cell electric potentials across a selectable grid.

Why Rebar Location and Corrosion Assessment Matter

Before executing any structural modifications, repairs, or maintenance, obtaining an accurate map of the internal reinforcement and its chemical state is essential:

  1. Ensuring Pre-Drilling and Pre-Core Safety: Drilling or coring into a load-bearing reinforcing bar can severely weaken a concrete member and cause immediate structural danger. Scans with a rebar scanner for concrete protect both the asset and the cutting tools from expensive damage.
  2. Predicting Structural Durability: Concrete cover acts as a barrier against carbonation, chloride ingress, and moisture. Verifying cover thickness helps engineers evaluate the long-term protection of the steel.
  3. Evaluating Degradation Trends: Detecting the potential for active corrosion before physical signs (such as cracking, rust staining, or spalling) appear is crucial for extending the service life of bridge decks, highways, and building foundations.
  4. Optimizing Rehabilitation Budgets: Identifying localized corrosion hot spots allows asset managers to plan targeted maintenance rather than resorting to complete, costly structural overhauls.

The QualiRLCT™ 50B is optimized for high-frequency field testing across numerous infrastructure assessment workflows:

  • Concrete Cover Thickness Testing: Verifying that the protective concrete barrier meets design specifications on newly completed structural members.
  • Internal Reinforcement Position Mapping: Identifying the exact layout, spacing, and depth of rebar networks before starting renovations or extensions.
  • Pre-Drilling and Pre-Core Testing Assessment: Scanning concrete surfaces prior to anchor installation, drilling, or core sampling to avoid cutting steel.
  • Rebar Corrosion Assessment: Mapping the half-cell potential grid on marine infrastructure, bridge decks, and highway supports to monitor environmental degradation.
  • Structural Condition Evaluation: Performing routine and specialized inspections on buildings, highways, tunnels, parking garages, and transport infrastructure.

The QualiRLCT™ 50B features a high-sensitivity electromagnetic sensor designed to map reinforcement parameters across standard and heavy-duty concrete structures:

  • Sizing and Depth Range: Supports the detection of standard steel bars ranging from a diameter of 6 mm to 50 mm.
  • Dual-Range Cover Measurement: Incorporates a low-range depth setting (6 mm to 90 mm) for precision cover checks on standard beams and slabs, and a high-range depth setting (7 mm to 180 mm) for thick concrete covers found in civil infrastructure and bridge piers.
  • Accurate Diameter Identification: Automatically identifies the bar diameter (from 6 mm to 50 mm) with a permissible diameter error of within 1 grade.
  • Grid and Line Scanning: Software interface supports continuous scanning paths to build a real-time visual representation of rebar spacing and reinforcement position distribution.

Corrosion Testing Capabilities

The chemical health of the reinforcing steel is evaluated using standard half-cell potential methodology:

  • Potential Measurement: Measures the potential difference up to 1000 mV with high-resolution accuracy of 1 mV.
  • Adjustable Measuring Grid: Allows operators to customize the measuring space from 1 cm to 99 cm, providing flexibility for localized, high-density checks or broad, fast-interval structural mapping.
  • Reference Electrode Support: Works in tandem with high-stability reference electrodes to deliver stable and repeatable potential readouts in fluctuating field conditions.

Operational Benefits

  • Safer Non-Destructive Operation: Replaces invasive, destructive chipping and exposure testing, significantly reducing inspection time and labor costs.
  • Exceptional Battery Independence: Powered by 6 standard dry cells, providing more than 30 hours of continuous active field operating time.
  • All-Weather Structural Assessment: Engineered to perform reliably across a wide operating temperature range from -10 degrees Celsius to +40 degrees Celsius.
  • Low-Interference Design: Specifically shielded to ensure accurate readings in construction environments without strong alternating electromagnetic fields.
  • User-Friendly Software Interface: Features a clear display that presents real-time depth measurements, spacing data, and corrosion curves for immediate analysis.
  • Rugged and Portable Packaging: Extremely lightweight handheld housing designed to endure the dust, humidity, and mechanical vibration typical of construction jobsites.

Rebar Detection

  • Applicable Steel-Bar Diameter: Dia. 6 mm to dia. 50 mm
  • Tested Range of Concrete Cover Thickness (Low Range): 6 mm – 90 mm
  • Tested Range of Concrete Cover Thickness (High Range): 7 mm – 180 mm
  • Tested Range of Steel-Bar Diameter: Dia. 6 mm to dia. 50 mm
  • Permissible Error of Steel-Bar Diameter: 1 grade
  • Power Supply: 6 dry cells
  • Active Operating Time: More than 30 hours
  • Working Environment Temperature: -10 degrees Celsius to +40 degrees Celsius
  • Working Environment Humidity: Less than 90 percent RH
  • Electromagnetic Interference Requirement: No strong electromagnetic field

Corrosion Detection

  • Measuring Potential: 1000 mV
  • Measuring Accuracy: 1 mV
  • Measuring Space: 1 cm to 99 cm (Adjustable)
  • Power Supply: 6 dry cells
  • Active Operating Time: More than 30 hours
  • Ambient Temperature Range: -10 degrees Celsius to +40 degrees Celsius (Avoid direct exposure to the sun for long periods)
  • Relative Humidity: Less than 90 percent RH
  • Electromagnetic Interference Requirement: No strong alternating electromagnetic field

Experience the Qualitest advantage and see how we can elevate your testing and quality control processes.

Please contact us for pricing, check availability, or ask for additional information about:

Rebar Locator & Corrosion Tester QualiRLCT™ 50B