Thickness Gauge Dual Element Transducer
Dual Element Thickness Gauge Transducers improve one-sided thickness measurement by separating transmit and receive crystals in one housing. The geometry improves near-surface focus and helps inspectors read thin, pitted, or hard-to-access sections on metals, plastics, composites, and fiberglass.
Description
Applications
Features
Specifications
Standard single-element probes suffer from near-surface dead zones and internal echo reflections, resulting in distorted data when evaluating thin or heavily pitted materials from one side. The Thickness Gauge Dual Element Transducer range solves this limitation by dividing the pulse cycle across independent transmitting and receiving crystals housed in a single probe.
Separated by an acoustic barrier to prevent cross-talk, this specialized Dual-Crystal Architecture uses precise crystal angling to focus ultrasonic signals directly beneath the entry surface. Available in frequencies ranging from 1.00 MHz to 10.00 MHz and diameters down to 3/16″, it easily adapts to tight geometries, complex surface curvatures, and highly attenuative cast irons.
To endure severe industrial conditions, the series offers specialized Hi Temp2 variants that operate safely on live, hot surfaces up to 335°C (635°F) without inducing thermal drift. When paired with compatible gauges, select probes utilize customized Coating Thickness (CT) damping to activate ThruPaint™ mode, enabling technicians to bypass protective claddings and measure underlying metal walls directly.
Engineered for seamless cross-platform integration, these transducers support the CX, ZX, MX, and CMX instrument families. They provide traceably accurate, project-ready data for long-term corrosion tracking, structural integrity monitoring, and batch quality control across metal alloys, engineering polymers, and layered fiberglass composites.
Thickness Gauge Dual Element Transducer models are utilized for one-sided material evaluation and NDT inspection in various industrial workflows:
- One-Sided Material Access: Measuring wall thickness on large structures where reaching the opposite side is impossible, such as storage tanks and pressurized vessels.
- Metal Substrate Inspection: Verifying the integrity of steel, aluminum, and titanium components in manufacturing and maintenance.
- Plastic Thickness Measurement: Inspecting molded or extruded polymer parts for wall consistency.
- Composite and Fiberglass Testing: Evaluating the thickness of fiberglass-reinforced plastics (FRP) and layered composite structures.
- Near-Surface Thickness Measurement: Utilizing angled crystal designs to achieve precise focus on thin-walled materials.
- Replacement Probe Selection: Providing a comprehensive range of compatible transducers for the CX 2, CX 4, CX6-DL, and CX8-DL series.
- Asset Integrity Monitoring: Supporting probes for the ZX Range, MX Range, and CMX Range to track corrosion and erosion over time.
- High-Temperature Inspections: Utilizing specialized “Hi Temp2” variants for measurement on hot surfaces up to 335°C (635°F).
The dual element transducer series integrates mechanical stability with optimized crystal layout to support precision metrology:
- Dual-Crystal Architecture: Features a transmit crystal and a receive crystal in one housing to eliminate the “dead zone” associated with single-element pulse-echo delay.
- Acoustic Barrier Separation: Includes a physical barrier between the two crystals to prevent cross-talk and minimize internal reflections.
- Focused Near-Surface Resolution: Employs angled crystal positioning to improve signal acquisition on thin materials and irregular back-wall surfaces.
- Broad Frequency Range: Available in 1.00 MHz, 2.25 MHz, 3.50 MHz, 5.00 MHz, 7.50 MHz, and 10.00 MHz groups to match specific material attenuation.
- Versatile Diameter Selection: Offered in 3/16″, 1/4″, and 1/2″ diameters to accommodate restricted access areas and various surface curvatures.
- Specialized Characteristics: Includes options for Standard, High Resolution, Low Profile, Armoured, Composite, and Cylinder probes for iron or aluminum.
- Multiple Damping Options: Supports technical damping levels including S (Standard), H (Highly Damped), and CT (Damped Coating Thickness).
- Rugged Connectivity: Features various connector configurations including Potted, Top, Side, Microdot, and Lemo to match instrument requirements.
- ThruPaint™ Capability: Selected models support measurement through coatings without removing the finish when used with compatible instruments.
Transducer Selection Guidance
Choosing the correct Dual Element Thickness Transducer requires matching the probe to both the material and the specific gauge model. Buyers should first identify instrument compatibility (e.g., ZX Range vs. CX series). Frequency selection should be based on material type; lower frequencies (1.00–2.25 MHz) are typically used for high-attenuation materials like cast iron or thick plastics, while higher frequencies (7.50–10.00 MHz) are used for high-resolution measurement of thin metals. Probe diameter should be selected based on the surface geometry, with smaller 3/16″ probes suited for curved or narrow surfaces. Finally, environmental factors like surface temperature and the presence of coatings (ThruPaint™) will determine if specialized “Hi Temp2” or “CT” damped probes are required.
Compatibility and Part Number Groups
Transducer options are organized by frequency and instrument range to facilitate correct ordering and technical matching:
CX-Compatible TXC Transducers
| Frequency | Part Number | Diameter | Characteristic | Damping |
| 1.00 MHz | TXC1M00EP-2 | 1/2″ | Standard | S |
| 5.00 MHz | TXC5M00CP-4 | 1/4″ | Standard | S |
| 5.00 MHz | TXC5M00CP-10 | 1/4″ | Standard | H |
| 5.00 MHz | TXC5M00CP-8 | 1/4″ | Hi Temp2 | S |
| 5.00 MHz | TXC5M00EP-10 | 1/2″ | Standard | H |
| 7.50 MHz | TXC7M50BP-3 | 3/16″ | Standard | S |
| 7.50 MHz | TXC7M50CP-4 | 1/4″ | High Resolution | S |
ZX / MX / CMX / R9 / PR8-DL / FX Compatible T-Series Transducers
| Frequency | Part Number Examples | Characteristic | Damping Options |
| 1.00 MHz | T-004-0000, T-104-0000 | Standard, Hi Temp2 | S, H |
| 2.25 MHz | T-002-1000, T-102-1000 | Standard, Hi Temp2 | S, H |
| 3.50 MHz | T-042-1000, T-242-1001 | Standard | S, H |
| 5.00 MHz | T-001-2000, T-101-2000 | Standard, Low Profile | S, H, CT |
| 7.50 MHz | T-001-3000, T-101-3900 | Standard, High Res | S, H |
| 10.00 MHz | T-101-4000, T-001-4000 | Standard, High Res | S, H |
Damping and Temperature Notes
Accuracy and safety in varied environments are supported by specific damping and thermal ratings. The S (Standard Damping) probes are suitable for most general measurements. H (Highly Damped) probes are required for high-resolution waveform analysis, while CT (Damped Coating Thickness) probes are specifically tuned for measuring through surface layers.
- Standard Transducers: Maximum temperature range of 126°C / 260°F.
- High Temperature Transducers (Hi Temp2): Maximum temperature range of 335°C / 635°F.
General Design
- Transducer Design: Dual element (Transmit / Receive architecture)
- Internal Barrier: Integrated acoustic barrier to prevent cross-talk
- Orientation: Angled crystal layout for near-surface signal focus
- Surface Access: Optimized for one-sided material measurement
Materials and Substrates
- Ferrous Metals: Steel, Iron, Stainless Steel
- Non-Ferrous Metals: Aluminum, Copper, Titanium
- Non-Metallic: Plastics, Composites, Fiberglass, Glass
Instrument Compatibility Summary
| Transducer Range | Compatible Instruments |
| TXC Series | CX 2, CX 4, CX6-DL, CX8-DL |
| T-Series | ZX Range, MX Range, CMX Range, R9, PR8-DL, FX70, FX80 |
Part Number Reference (T-Series Selection)
| Part Number | Frequency | Diameter | Characteristic |
| T-104-0600 | 1.00 MHz | 1/2″ | Hi Temp2 |
| T-204-0001 | 1.00 MHz | 1/2″ | Standard (Top Conn.) |
| T-302-1001 | 2.25 MHz | 1/4″ | Standard (Side Conn.) |
| T-121-2100 | 5.00 MHz | 1/4″ | Low Profile (Wand) |
| T-104-2120 | 5.00 MHz | 1/2″ | Composite |
| T-162-4110 | 10.00 MHz | 1/4″ | High Resolution |
Experience the Qualitest advantage and see how we can elevate your testing and quality control processes.
Please contact us for pricing, check availability, or ask for additional information about: