Ultrasonic Corrosion Thickness Gauge MX2-DL
MX2-DL adds waveform validation to through-coating corrosion checks, helping inspectors confirm questionable readings before they become costly calls. A-scan, B-scan, two gates, Pulse-Echo and Echo-Echo modes, 4 GB memory, and USB-C output support more defensible reporting on pipes and structures.
Description
Applications
Features
Specifications
Scraping off thick protective coatings to map corrosion or diagnose internal pitting compromises structural assets and introduces heavy manual overhead. The Ultrasonic Corrosion Thickness Gauge MX2-DL completely eliminates this operational bottleneck by delivering high-precision material evaluation without surface preparation.
Powered by a 100MHz DSP platform and a 150V square wave pulser, this dual-element NDT instrument features advanced Echo-Echo (E-E) ThruPaint™ capabilities to bypass surface coatings up to 6.0 inches thick. It features two independent measurement gates for total signal control, alongside high-resolution A-Scan (RF and Rectified) waveforms and time-based 2D B-Scan cross-sections to visually validate internal thinning patterns.
Engineered for severe environments, the MX2-DL is packaged in a gasket-sealed extruded aluminum body rated from -10°C to 60°C. It records thousands of multi-point metrics within its 4GB internal memory and captures real-time .tif screen images, utilizing a direct USB-C 1.1 data interface (Windows/OSX compatible) to provide project-ready, NIST-traceable asset integrity reporting.
The MX2-DL is optimized for rigorous surface verification and analytical NDT workflows where signal validation is critical:
- In-Depth Corrosion Thickness Measurement: Monitoring wall loss in high-stakes industrial infrastructure with full waveform validation.
- Pit and Flaw Detection: Utilizing Pulse-Echo mode and A-Scan visualization to identify and qualify localized pitting or structural defects.
- Thru-Paint / Coating Measurement: Measuring base metal thickness through protective layers up to 6.0 inches without surface preparation.
- Waveform Interpretation: Performing RF and Rectified signal reviews to ensure gate triggers are optimized for complex material geometries.
- Multi-Gate Measurement Control: Utilizing two independent gates to isolate and monitor specific echoes in challenging measurement environments.
- Cross-Sectional Review: Leveraging the time-based B-Scan view to visualize the opposite surface profile and identify internal thinning patterns.
- Minimum Thickness Scanning: Pinpointing the absolute thinnest area of a workpiece using the high-speed 250Hz scan mode.
- Professional Field Documentation: Utilizing the 4GB memory and USB-C 1.1 connectivity to generate comprehensive inspection reports for maintenance audits.
The MX2-DL integrates sophisticated signal processing with rugged field hardware to optimize measurement precision:
- Dual-Mode Analytical Versatility: Supports P-E for bulk flaws and E-E for through-coating measurement, backed by real-time A-Scan and B-Scan visualization.
- Advanced Waveform Review: Features A-Scan displays with +Rectified, -Rectified, and Full Waveform (RF) modes to assist with precise echo interpretation.
- Enhanced Measurement Control: Equipped with two independent gates to provide superior stability in signal acquisition across different measurement modes.
- Precision Signal Management: Features manual or Automatic Gain Control (AGC) with a 50dB range and Linear Time-Dependent Gain (TDG) built into each transducer type.
- Adjustable Pulse Performance: Utilizes a 150-volt square wave pulser with adjustable pulse widths (spike, thin, wide) to optimize penetration.
- High-Speed Data Acquisition: Captures up to 250 readings per second in scan mode, automatically identifying the minimum thickness encountered.
- Intelligent Tool Setup: Includes automatic or manual transducer recognition and built-in dual path error correction to ensure measurement linearity.
- Massive Data Logging: Features 4GB of internal memory with a Grid alphanumeric structure and .tif screen capture for quick field documentation.
- Modern Connectivity: Equipped with a direct USB-C 1.1 interface compatible with both Windows® PC and OSX interface software.
- Ruggedized Construction: Built with an extruded aluminum body and gasket-sealed end caps to survive temperatures from -14° to 140°F (-10° to 60°C).
- Guaranteed Reliability: NIST-traceable factory calibration is standard, supported by a 2-year limited warranty.
Pulse-Echo and Echo-Echo Measurement Modes
Operational accuracy is supported by matching the measurement mode to the specific surface condition of the asset. The Pulse-Echo (P-E) Mode serves as the primary tool for pit and flaw detection in base materials, offering an extensive range from 0.025 to 100 feet (0.63 to 30.48 meters). For maintenance of coated infrastructure, the Echo-Echo (E-E) Mode activates the ThruPaint™ workflow. This mode measures the time-of-flight between successive echoes to obtain accurate base material data while ignoring protective coatings. Technical teams can utilize single or two-point calibration options alongside a selection of basic material types to maintain precision across a broad velocity spectrum.
A-Scan, B-Scan, Large Digits, and Display Review
The user interface of the MX2-DL is designed for high-visibility data interpretation. The A-Scan view provides a traditional waveform representation, allowing technicians to validate the reflected signal in RF or Rectified formats. For cross-sectional interpretation, the B-Scan mode provides a time-based 2D visualization of the material profile. For rapid standard audits, the Large Digits view presents the thickness value with a 0.700-inch height. Operators can monitor thickness variations via the Scan Bar, which updates at 10Hz, while the six-bar Bar Graph provides real-time feedback on measurement stability.
Gates, Transducer, Gain, and Signal Control
Technical flexibility is supported by compatibility with dual-element transducers ranging from 1 to 10MHz. The MX2-DL distinguishes itself with two independent gates, allowing the user to set specific monitoring windows for echo verification. Signal acquisition is managed by a 150-volt square wave pulser and precision TCXO timing. The 50dB gain range and the Linear Time-Dependent Gain (TDG) allow the operator to adjust sensitivity for attenuative materials, while the built-in dual path error correction ensures results remain linear even at the extremes of the measurement range.
Memory, USB-C Output, and Documentation
The MX2-DL serves as a high-capacity hub for traceable inspection data. Its 4GB internal memory organizes thousands of readings into Grid alphanumeric formats, supporting organized multi-point audits. For immediate field documentation, the Screen Capture feature saves current views as .tif files. Data transfer is managed through a direct USB-C 1.1 connection, allowing for full integration with the included Windows® and OSX interface software for historical analysis and professional report generation. Users can also manage and edit up to 64 custom configurations to maintain standardized testing protocols.
Physical Design
| Item | Specification |
| Weight | 13.5 ounces (383g) with batteries |
| Dimensions | 2.5 W x 6.5 H x 1.24 D inches / 63.5 W x 165 H x 31.5 D mm |
| Operating Temp. | -14° to 140°F (-10° to 60°C) |
| Keyboard | Membrane switch with twelve tactile keys |
| Case Material | Extruded aluminum body; gasket sealed |
Display and Visualization
| Item | Specification |
| Display Type | 1/8in VGA grayscale (240 x 160 px), EL Backlit |
| Refresh Rate | 25Hz |
| A-Scan Views | Rectified +/- flaw view, RF full waveform view |
| B-Scan View | Time-based cross section |
| B-Scan Speed | Variable, 10 to 200 readings per second |
| Large Digits | 0.700 in / 17.78mm height |
| Indicators | 10Hz Scan Bar, Measurement Stability Bar Graph |
Measuring Performance
| Feature | Specification |
| Measurement Range (P-E) | 0.025 to 100 ft. (0.63 to 30.48 M) |
| Measurement Range (E-E) | 0.100 to 6.0 in (2.54 to 152.4mm) |
| Resolution | +/- .001 inches (0.01mm) |
| Velocity Range | 309.88 to 18542 m/sec (0.0122 to 0.7300 in/µs) |
| Scan Mode Rate | 250 readings per second (min value capture) |
Ultrasonic Specifications
| Feature | Details |
| Pulser Type | 150V Square wave; adjustable width (spike, thin, wide) |
| Timing / Digitizer | Precision TCXO; 100MHz 8-bit digitizer |
| Measurement Modes | Pulse-Echo (P-E), Echo-Echo (E-E) |
| Gate Control | Two independent gates |
| Gain Control | Manual or AGC (50dB range) |
| Transducer Type | Dual Element (1 to 10MHz); LEMO “00” |
Data, Memory, and Connectivity
| Feature | Details |
| Internal Memory | 4Gb capacity; .tif bitmap screen capture |
| Logging Formats | Grid Alpha Numeric; 64 custom setups |
| Output Port | USB-C 1.1 (Windows® & OSX compatible) |
| Battery / Life | 3 AA cells / 35 hrs (Alkaline) |
| Certification | NIST & MILSTD-45662A Traceable |