Ultrasonic Precision Thickness Gauge – PZX Series
PZX Series is built for thin-material work where small measurement errors can drive scrap or machining rework. With 120 MHz FPGA timing, a 100-volt spike pulser, multiple echo modes, and ThruPaint capability, it delivers precise gauging on metals, plastics, and other thin sections.
Description
Applications
Features
Specifications
Measuring ultra-thin foils, plastics, and precision stampings often causes severe coupling errors and data drift on standard gauges. The PZX Series Ultrasonic Precision Thickness Gauge solves this pain point, utilizing a 100-volt spike pulser and 120MHz FPGA timing to secure stable 0.0001-inch resolution.
Featuring single-element delay line capabilities, this portable non-destructive testing (NDT) instrument accommodates specialized evaluation across four selectable measurement modes. It effortlessly measures thin-walled polymer products, aircraft skins, and high-tolerance electronics components without requiring destructive testing or sample cutting.
Fully compliant with ASTM E797 and ISO 16809 standards, the series eliminates complicated data management overhead. The advanced PZX1-DL model records up to 10,000 readings, exporting standard software-free CSV files via USB-C to rapidly accelerate factory-floor quality control workflows.
The PZX Series provides versatile NDT solutions across specialized manufacturing and maintenance sectors:
- Precision Machining and Stamping: Verifying tight tolerances on machined parts and stamped metal components.
- Thin Substrate Measurement: Evaluating the thickness of thin foils, shims, and precision-engineered substrates.
- Aircraft and Automotive Inspection: Performing non-destructive checks on aircraft skins and vehicle components where material uniformity is required.
- Thin Plastics Evaluation: Utilizing the specialized Plastics mode to measure thin-walled polymer products and films.
- Material Homogeneity Review: Using velocity measurement and VX velocity for nodularity testing and material consistency audits.
- High-Speed Surface Scanning: Utilizing the high-speed scan mode to capture minimum thickness values over larger inspection areas.
- Tolerance and Quality Audits: Setting high and low alarm limits for rapid pass/fail judgment on the production floor.
- Differential Thickness Comparison: Monitoring material loss or deviation by comparing live readings against a nominal value.
- PZX1-DL Sequential Data Storage: Managing 10,000 readings across 40 files for comprehensive reporting and digital traceability.
The PZX Series integrates advanced timing hardware with flexible measurement software to optimize precision inspection:
- High-Resolution Performance: Supports selectable resolutions including 0.001 or 0.0001 inches (0.01 or 0.001 mm) for exacting requirements.
- Multi-Mode Flexibility: Offers Pulse-Echo, Echo-Echo, Interface-Echo, and Plastics modes to match diverse material characteristics.
- ThruPaint™ Technology: Supports precision measurement through thin coatings, providing accurate substrate data without removal of the finish.
- Advanced Pulse Generation: Features a 100-volt spike pulser and 120MHz FPGA timing to maintain signal integrity on thin specimens.
- Automatic Time-Dependent Gain (TDG): Implements TDG across all measurement modes with a manual gain override for complex inspection setups.
- Single-Element Transducer Support: Compatible with single-element delay line and contact transducers ranging from 5 to 20MHz.
- Rugged Physical Design: Housed in an extruded aluminum body with gasket-sealed nickel-plated aluminum end caps for industrial durability.
- Low-Temperature Readability: Equipped with a custom LCD display designed for operation in temperatures as low as -22°F / -30°C.
- Software-Free Data Workflow: The PZX1-DL outputs data in CSV format via USB-C, requiring no specialized software for PC-based analysis.
- Traceable Calibration Support: Factory calibration is traceable to NIST and MIL-STD-45662A, supported by a 5-year limited warranty.
PZX1 and PZX1-DL Model Selection
The PZX Series is tiered based on data management and logging requirements:
- PZX1 Precision Thickness Gauge (PZX-7): The standard precision model (Part No: Z-307-0002) optimized for digits-only thickness display. It includes high-speed scan, differential, and alarm modes but does not feature internal storage.
- PZX1-DL Precision Thickness Gauge (PZX-7 DL): The advanced data-logging version (Part No: Z-308-0002). It maintains the same high-resolution ranges as the PZX1 while adding 32-megabit flash memory. This version supports sequential data storage for 10,000 readings (40 files of 250 readings) and comes complete with a USB-C download cable.
Measurement Modes and Range
Accuracy is maintained through specialized algorithms tailored to the sample geometry and material type. Ranges vary based on transducer selection and material properties:
- Pulse-Echo (P-E): Measures total material thickness from 0.63 to 914.4 mm (0.025 to 36 inches).
- Echo-Echo (E-E): Measures through delay lines (0.152 to 25.4 mm / 0.006 to 1 inch) or via contact (1.0 to 152.4 mm / 0.040 to 6.0 inches).
- Interface-Echo (I-E): Utilizes a single-element delay line for measurement between 1.524 and 25.4 mm (0.060 to 1.0 inch).
- Plastics (PLAS): Uses a graphite delay line for specialized measurement of thin plastics from 0.127 to 6.35 mm (0.005 to 0.250 inches).
The system supports a broad velocity calibration range from 305 to 18,542 m/s (0.0120 to 0.7300 in/μs), allowing for the evaluation of a wide variety of good ultrasonic wave conductors.
Scan, Differential, Alarm, Gain, and Velocity Workflow
The PZX Series provides technical teams with tools to streamline the inspection process. The High-Speed Scan mode captures data at 100Hz and displays the lowest reading found during the sweep. For deviation monitoring, the Differential Mode shows the plus/minus difference from a nominal value. The Alarm Mode provides audible and visual indicators for high and low limits.
Advanced receiver control is managed via the Time-Dependent Gain (TDG), which compensates for signal attenuation automatically in all modes. For material research, the VX Velocity function measures the speed of sound directly, supporting nodularity testing and consistency checks. A stability bar graph provides the operator with immediate feedback on reading reliability.
Transducers, Display, Connectivity, and Data
The PZX Series is designed for long-term operational flexibility. Transducers are recognized manually from a selectable list, and the instrument features an integrated probe disk for manual zeroing. The display utilizes 12.7 mm (0.5 inch) high digits and multi-function labels for clear mode identification. Connectivity is handled through a USB-C port, which provides both line power and data transmission. For the PZX1-DL, the 32-megabit flash memory stores sequential data that is exported as a standard .csv file, ensuring compatibility with any laboratory or production management system. Optional modules for serial RS232 or Bluetooth are available for specialized facility integrations.
Measurement Modes and Ranges
| Mode | Metric Range | English Range |
| Pulse-Echo (P-E) | 0.63 to 914.4 mm | 0.025 to 36 inches |
| Echo-Echo (E-E) | 0.152 to 25.4 mm (Delay) | 0.006 to 1 inch (Delay) |
| Interface-Echo (I-E) | 1.524 to 25.4 mm | 0.060 to 1.0 inch |
| Plastics (PLAS) | 0.127 to 6.35 mm | 0.005 to 0.250 inches |
Resolution, Velocity, and Timing
| Feature | Specification |
| Resolution Ratio | 0.001 or 0.0001 inch / 0.01 or 0.001 mm |
| Velocity Calibration Range | 305 to 18,542 m/s (0.0120 to 0.7300 in/μs) |
| Internal Timing | 120MHz FPGA Timing |
| Pulser Type | 100-Volt Spike Pulser |
| Display Refresh Rate | 25Hz |
| Pulse Repetition Freq. | 200Hz |
Transducer and Probe Setup
| Feature | Specification |
| Transducer Type | Single Element (Delay Line or Contact) |
| Frequency Range | 5 to 20MHz |
| Transducer Recognition | Manual (Selectable from list) |
| Probe Zero | Manual via integrated probe disk |
| Connectors | Locking quick disconnect LEMO |
| Cable | 4-foot shielded cable |
Data, Software, and Connectivity
| Feature | PZX1 (Basic) | PZX1-DL (Logging) |
| Data Storage | N/A | 10,000 readings (40 files x 250) |
| File Format | N/A | Comma Separated Value (.csv) |
| USB Connectivity | USB-C (Power/Data) | USB-C (Power/Data/Export) |
| Optional Modules | RS232, Bluetooth | RS232, Bluetooth |
| Memory Capacity | N/A | 32-Megabit Flash |
Power and Physical Details
| Feature | Specification |
| Operating Temp. | -22 to 167°F / -30 to 75°C |
| Power Supply | 2 × AA Batteries (Alkaline, Lithium, or NiCad) |
| Battery Life | 35 Hours (Alkaline) / 18 Hours (NiCad) |
| Gauge Dimensions | 63.5 × 131 × 31.5 mm (2.5 × 5.17 × 1.24 inches) |
| Gauge Weight | 312 g (11 oz) including batteries |
| Auto Shut-off | 5 Minutes of inactivity |
Packing List
- PZX1 or PZX1-DL Unit
- Standard 1/4″ Delay Line Transducer
- Replacement Delay Tips (3/8” and 1/2” L)
- Transducer Cable
- Ultrasonic Couplant
- Operation Manual
- NIST Traceable Certificate of Calibration
- AA Batteries
- Rugged Plastic Carrying Case
Experience the Qualitest advantage and see how we can elevate your testing and quality control processes.
Please contact us for pricing, check availability, or ask for additional information about: