Ultrasonic Thickness Gauge – QTG III
QTG III addresses corrosion checks on coated assets by measuring through paint without stripping the surface first. Its pocket-size body, automatic probe setup, 5,000-reading memory with location numbers, scan mode, and USB transfer help inspectors document wall loss faster in the field.
Description
Applications
Features
Specifications
Scraping protective industrial coatings for wall thickness audits causes structural damage and massive downtime. The pocket-sized QTG III solves this challenge by deploying advanced non-destructive testing (NDT) to accurately measure metal walls without removing surface paint or protective enamels.
Engineered for absolute technical precision, this portable instrument utilizes Echo-Echo (E-E) and Transmitter-Echo (T-E) measurement modes. It ensures strict compliance with ISO 16809 and ASTM E797 standards, providing rapid, highly accurate sub-surface corrosion tracking across severe operational environments.
Featuring continuous zero calibration and location-based data logging, the system eliminates human logging errors. It handles 5,000 readings and exports directly via USB, while a high-speed scan mode optimizes laboratory and high-temperature pipeline inspection throughput smoothly.
The QTG III is optimized for a broad array of professional inspection and quality control tasks:
- Through-Coating / Thru-Paint Measurement: Evaluating metal wall thickness through surface coatings, enamels, or paints using E-E mode.
- Non-Destructive Material Inspection: Verifying the integrity of structural components without causing damage to the substrate or finish.
- Curved Surface Measurement: Utilizing the “Minimum Measurement” mode to identify the thinnest point on pipes, tubes, and other curved geometries.
- Industrial Maintenance and Corrosion Monitoring: Tracking wall loss over time in pipelines and storage tanks to ensure safe operational limits.
- High-Temperature Inspections: Leveraging the “Scan Mode” at 10 measurements per second for rapid data acquisition in elevated temperature workflows.
- Differential and Average Quality Checks: Comparing actual thickness against a user-entered reference value or averaging data across 2 to 9 points for batch consistency.
- Laboratory and Field Reporting: Utilizing the 5000-reading memory and USB output for professional documentation and digital traceability.
The QTG III integrates sophisticated sensing intelligence with a compact, handheld architecture to enhance field efficiency:
- Integrated Thru-Paint Capability: Features an E-E (Echo-Echo) mode that facilitates substrate measurement through coatings, saving time on surface preparation.
- Pocket-Sized Portability: A lightweight and ergonomic design that fits easily into a field kit for point-of-need inspection.
- Automated Tool Setup: Includes automatic probe identification and automatic zero calibration at power-up and continuously during measurement cycles.
- Versatile Measurement Modes: Supports T-E (Standard, Minimum, Differential, Average, Limit), E-E (Through-Coating), and high-speed Scan modes.
- Sophisticated Gain Control: Offers automatic gain adjustment along with manual settings (Low, Standard, High) to adapt to varied material densities.
- Advanced Data Management: Stores up to 5000 readings with unique location numbers for organized historical review and reporting.
- Material Velocity Flexibility: Includes 9 pre-stored material velocities and allows for manual input from 1000 to 9999 m/s.
- Professional Information Display: The 128 × 64 graphics LCD displays the thickness reading alongside probe type, velocity, mode, and battery status.
- Standardized Digital Connectivity: Features a USB interface for rapid data transfer to a PC for analysis and formal report generation.
- Extended Field Readiness: Powered by two AAA alkaline batteries providing up to 50 hours of operation (without backlight).
T-E, E-E, and Scan Measurement Modes
Operational versatility is defined by the unit’s tiered measurement architecture. The T-E (Transmitter-Echo) mode is used for standard material evaluation and includes specialized sub-modes for curved surfaces (Minimum), comparative analysis (Differential), and statistical review (Average and Limit). The E-E (Echo-Echo) mode is the dedicated Thru-Paint feature, allowing for accurate metal wall assessment while ignoring the thickness of the applied coating. For high-throughput requirements or inspections at elevated temperatures, the Scan mode captures and displays thickness data at a rate of 10 measurements per second, providing the actual thickness values in real-time.
Probe Setup, Velocity, and Gain Control
Accuracy in varied environments is maintained through automated and manual setup routines. The QTG III automatically recognizes the connected probe type and maintains a continuous zero calibration during the inspection to prevent drift. Users can optimize the instrument’s sensitivity for complex materials by manually adjusting the gain between low, standard, and high settings. To match specific material characteristics, operators can select from stored velocities or manually calibrate the instrument against a known thickness to determine the precise sound velocity of a new material.
Memory, USB Output, and Reporting Workflow
The QTG III serves as a comprehensive tool for traceable inspection documentation. Unlike basic models, it features a 5000-reading memory capacity that allows each measurement to be tagged with a location number. This data structure facilitates large-scale audits across multi-point assets. The standard configuration includes specialized software and a USB cable, enabling technical teams to move field data to a computer for archival and analysis. The monochrome graphics LCD provides all necessary metadata at a glance, ensuring that the operator is aware of the current measurement mode and velocity settings at all times.
Optional Transducers
While the standard configuration includes the 5 MHz D5301 transducer, the QTG III can be equipped with various optional probes to meet specific frequency, temperature, and range requirements:
| Model | Frequency | T-E Range | E-E Range | Diameter | Temp Limit |
| D5301 (Std) | 5.0 MHz | 0.65 – 400 mm | 3 – 25 mm | Ø10.8 | < 60℃ |
| D5008 | 5.0 MHz | 0.8 – 300 mm | N/A | Ø10.8 | < 60℃ |
| D5113 | 5.0 MHz | 3.0 – 200 mm | N/A | Ø13.0 | < 350℃ |
| D7006 | 7.5 MHz | 0.7 – 50 mm | N/A | Ø8.5 | < 60℃ |
| D7004 | 10.0 MHz | 0.65 – 20 mm | N/A | Ø5.0 | < 60℃ |
| D2012 | 2.0 MHz | 2.0 – 400 mm | N/A | Ø16.3 | < 60℃ |
Measurement Modes and Setup
| Category | Specification |
| T-E Mode | Standard, Min, Diff, Avg (2-9 pt), Limit (with Alarm) |
| E-E Mode | Thru-Paint / Through-Coating Measurement |
| Scan Mode | 10 measurements per second (Ideal for High-Temp) |
| Probe Identify | Fully Automatic |
| Probe Zero | Auto at power-up; Continuous during measurement |
| Gain Adjustment | Auto; Manual (Low, Standard, High) |
Measuring Range and Resolution
| Feature | Specification |
| E-E Measuring Range | 3 to 25 mm (0.118 to 1 inch) |
| T-E Measuring Range | 0.65 to 400 mm (0.026 to 15.75 inches) |
| Resolution (<99.99 mm) | 0.01 mm / 0.001 inch |
| Resolution (>99.99 mm) | 0.1 mm / 0.01 inch |
| Velocity Range | 1000 m/s to 9999 m/s (9 Stored Velocities) |
Physical and Environmental
| Feature | Specification |
| Display | 128 × 64 Graphics LCD (Monochrome) |
| Memory Capacity | 5000 groups with location number |
| Output Interface | USB to PC |
| Battery / Life | 2 AAA Alkaline / Up to 50 hours (no backlight) |
| Operating Temp. | -20℃ to 50℃ |
| Weight / Size | 220 g / 115 × 64 × 27 mm |
Standard Configuration
- QTG III Main Unit
- Standard 5MHz Transducer (D5301)
- Built-in 4 mm Calibration Block
- Calibration Certificate
- Software and USB Connectivity Cable
- Two AAA Batteries
- Ultrasonic Couplant
- Detailed Operation Manual
- Rugged Carrying Case
Experience the Qualitest advantage and see how we can elevate your testing and quality control processes.
Please contact us for pricing, check availability, or ask for additional information about: