Ultrasonic Thickness Gauge – QTG IV
QTG IV reduces rework on coated parts by combining Echo-Echo thru-paint measurement with A-scan and B-scan views in one portable gauge. With 10,000-reading memory, USB output, and support for multiple probes, it helps inspectors verify wall thickness faster on complex materials and hot jobs.
Description
Applications
Features
Specifications
Video
Undetected subsurface flaws and the need to scrape protective coatings cause expensive material degradation and inspection downtime. The QTG IV Ultrasonic Thickness Gauge solves this by combining accurate Transmit-Echo and Echo-Echo measurement modes within a single portable NDT platform.
Featuring a 320 x 240 TFT color display, this instrument provides advanced A-scan and B-scan visualization. Technicians can instantly verify echo signals and cross-sectional profiles, eliminating blind spots and manual calculation errors during high-precision manufacturing quality control.
Fully compliant with ASTM E797 and ISO 16809 standards, the QTG IV delivers traceably accurate Thru-Paint thickness data up to 25 mm. Its driverless USB interface and 10,000-reading memory ensure swift data export to accelerate aerospace and automotive inspection workflows.
The Ultrasonic Thickness Gauge – QTG IV is utilized for comprehensive inspection and research tasks where visual waveform analysis is necessary:
- Non-Destructive Thickness Measurement: Performing precision checks on finished components without damaging the material or its surface finish.
- Thru-Paint / Coating Measurement: Utilizing Echo-Echo Mode to measure metal wall thickness through applied coatings, enamels, and paints.
- Standard Material Inspection: Evaluating metallic materials like steel, aluminum, and titanium, alongside non-metallic wave conductors such as plastics, ceramics, and glass.
- Advanced Waveform Review: Utilizing A-scan and B-scan views to interpret echo signals and visualize the material cross-section.
- Wall Thickness Monitoring: Monitoring integrity for materials with parallel top and bottom surfaces in field or laboratory settings.
- Production Quality Control: Verifying consistency during manufacturing processes with documented data logging for up to 10,000 readings.
- Extreme Temperature Testing: Executing inspections in environments ranging from -10°C to 50°C, with compatibility for high-temperature probes.
- Remote Field Documentation: Exporting data directly via USB to Windows-based systems for rapid report generation without the need for additional drivers.
The QTG IV combines sophisticated scanning technology with adjustable setup controls to optimize NDT workflows:
- Visual Waveform Analysis: Provides both A-scan and B-scan capabilities, allowing operators to verify readings through graphical signal interpretation.
- Dual-Mode Flexibility: Features T-E Mode for standard thickness (up to 400 mm) and E-E Mode for through-coating assessment.
- High-Resolution TFT Color Display: The 320 × 240 screen supports multi-view options, including large digits for readability and a real-time scan bar.
- Extended Internal Storage: Includes a built-in TIF card capable of storing 10,000 readings organized into 100 manageable files.
- Driverless Data Interface: Features a USB port that allows for direct data output to Windows (32-bit and 64-bit) without specialized installation.
- Precision Setup Control: Offers manual or auto gain control (50 dB range) along with adjustable Gate and Blank settings to refine signal acquisition.
- Intelligent Tolerance Management: Includes high and low limit modes with both audible beepers and visual LED alerts for rapid pass/fail judgment.
- Versatile Probe Compatibility: Supplied with a standard 5.0 MHz transducer and supports dual-element probes from 2 to 10 MHz.
- Metric and English Units: Supports seamless switching between millimeters and inches, including velocity readings in inches/ms.
- Rugged ABS Construction: Built for the field with a durable plastic case and a membrane switch keyboard featuring 8 tactile keys.
- Two-Year Limited Warranty: Backed by extended manufacturer protection for long-term operational reliability.
T-E, E-E, A-Scan, and B-Scan Workflow
Operational precision is supported by the ability to switch between numerical and graphical measurement representations. The Transmit-Echo (T-E) Mode serves as the standard tool for bulk material measurement, while the Echo-Echo (E-E) Mode activates the Thru-Paint feature for coated components. The A-scan view provides a traditional pulse-echo representation of the ultrasonic signal, which is critical for confirming that the gauge is triggered by the correct echo. For a more intuitive view, the B-scan provides a cross-sectional profile of the material as the probe is moved. These views are complemented by a scan bar that captures 10 readings per second, helping to identify thinning areas or internal irregularities quickly.
Measurement Modes and Tolerance Control
The QTG IV features several specialized measurement algorithms to suit different inspection goals:
- Standard Mode: Used for general-purpose, point-to-point thickness checks.
- Minimum Mode: Continuously tracks and displays only the thinnest value found during a scan.
- Difference Mode: Displays the delta between the actual measurement and a user-defined reference value.
- Average Mode: Calculates the mean value across 2 to 9 user-selected testing points.
- Limit Mode: Triggers visual LEDs and an audible beeper when measurements fall outside the pre-set Hi and Lo tolerance thresholds.
Data Memory, USB Output, and Windows Workflow
Documentation is handled through a built-in TIF card that organizes data using an English letter and alphanumeric naming structure. The 10,000-reading capacity is divided into 100 files, making it simple to separate different inspection projects. The QTG IV distinguishes itself with a true “plug-and-play” USB interface. When connected to a computer running Windows (64-bit or 32-bit), the data can be exported directly without installing third-party drivers, streamlining the transition from field data capture to official report generation.
Transducers, Gain, Gate, and Setup Control
To ensure accuracy on complex materials, the QTG IV provides deep control over the receiver settings. Operators can adjust the gain up to 50 dB manually to pick up weak signals or use auto-gain for standard tasks. The Blank and Gate settings allow for the exclusion of surface noise and the isolation of specific back-wall echoes. While the instrument is supplied with a standard 5.0 MHz dual-element transducer (1.25 m cable), it is compatible with a wide array of optional probes. This includes low-frequency probes for highly attenuative materials, high-frequency probes for thin sections, and high-temperature probes for in-service maintenance.
Measurement Modes and Setup
| Category | Specification |
| Ultrasonic Modes | Transmit-Echo (T-E) / Echo-Echo (E-E) |
| Workflow Modes | Standard, Minimum, Difference, Average (2-9 pt), Limit |
| Tolerance Indicators | Visual LEDs and Audible Beeper |
| Gain Control | Manual or Auto (50 dB range) |
| Receiver Adjustments | Gain, Gate, and Blank adjustable |
Measuring Range, Transducer, and Resolution
| Feature | Specification |
| E-E (Thru-Paint) Range | 3.00 to 25.00 mm (0.118 to 1.0 inch) |
| T-E (Standard) Range | 0.65 to 400.0 mm (0.025 to 15.75 inches) |
| Resolution | +/- 0.01 mm / 0.001 inch |
| Standard Transducer | 5.0 MHz Dual Element (1.25 m cable) |
| Supported Frequencies | 2 to 10 MHz (Dual Element) |
| Range Variance | +/- depending on coating thickness |
Velocity, Display, and Views
| Feature | Specification |
| Velocity Range (Metric) | 1000 to 9999 meters/sec |
| Velocity Range (English) | 0.492 to 0.3936 inches/ms |
| Display Type | 320 × 240 TFT Color Display |
| Large Digits View | Standard thickness representation |
| Scan Bar View | 10 readings per second; viewable in B-scan |
| Interface Language | Multiple languages supported |
Power, Physical, and Environmental
| Feature | Specification |
| Battery / Life | 2x 1.5V AA Alkaline / Typically 24 hours |
| Memory | 10,000 readings in 100 files (Internal TIF) |
| Output Port | USB (Driverless for Windows 32/64-bit) |
| Operating Temp. | -10°C to 50°C (-14°F to 662°F) |
| Unit Dimensions | 133 × 75 × 29 mm (5.2 × 3.0 × 1.1 inches) |
| Unit Weight | 260 g |
Experience the Qualitest advantage and see how we can elevate your testing and quality control processes.
Please contact us for pricing, check availability, or ask for additional information about: