Home / Products / ... / Other Portable Testers / Ultrasonic Thickness Gauge / Ultrasonic Thickness Gauge – ZX Series / Ultrasonic Thickness Gauge ZX1 / ZX2
Ultrasonic Thickness Gauge ZX1 / ZX2

Ultrasonic Thickness Gauge ZX1 / ZX2

ZX1 and ZX2 reduce everyday setup friction for routine wall-thickness checks on known materials. The rugged gauges pair 120 MHz FPGA timing with pulse-echo measurement, dual-element probes, and adjustable velocity; ZX2 adds stored material choices to speed work when technicians move across alloys.

Description

Applications

Features

Specifications

Routine thickness tracking on site often suffers from fragile equipment and tedious calibration menus, causing inspection delays and material failure risks. The Ultrasonic Thickness Gauge ZX1 / ZX2 series solves these issues by providing a highly stable, digits-only Pulse-Echo platform packaged in an ultra-rugged industrial shell.

Driven by a high-penetration 150V square wave pulser and 120MHz FPGA timing, this series handles a wide measuring range from 0.025 to 36.00 inches. Technical teams can tailor the instrument to their workflow: choose the standard ZX1 for manual keypad velocity entry, or upgrade to the ZX2, which features a built-in material selection list and eight factory presets to eliminate configuration guesswork when switching between steel, iron, or plastics.

Built to withstand extreme environments, the series is wrapped in a gasket-sealed extruded aluminum body with a low-temperature LCD rated down to -30°C (-22°F). Fully calibrated traceably to NIST and MIL-STD-45662A and backed by a 5-year limited warranty, these gauges deliver up to 45 hours of battery life to keep preventive maintenance and fabrication quality control moving efficiently.

The Ultrasonic Thickness Gauge ZX1 / ZX2 models are utilized for standardized material thickness verification across various industrial maintenance and quality control sectors:

  • Routine Material Inspection: Performing point-of-need checks on incoming raw materials and finished components in manufacturing and fabrication shops.
  • Preventive Maintenance: Monitoring wall thinning in tanks, pipes, and flat surfaces to identify potential failures before they occur.
  • Basic Corrosion Screening: Conducting initial structural integrity checks in oil and gas, utilities, and marine environments.
  • Fabrication Quality Assurance: Verifying machining tolerances and structural consistency during the production process.
  • Training and Educational Labs: Providing a reliable platform for demonstrating ultrasonic testing principles and material science fundamentals.
  • Field Inspection Workflows: Leveraging long battery life and rugged construction for onsite measurement in remote or outdoor locations.
  • Homogeneous Material Testing: Measuring consistent conductors such as steel, aluminum, plastics, and glass with high repeatability.

The ZX1 / ZX2 series integrates professional-grade sensing hardware with a simplified user interface to optimize routine NDT workflows:

  • Pulse-Echo Measurement Precision: Provides reliable thickness data by measuring the time-of-flight between the transmitted pulse and the return echo.
  • Dual-Element Transducer Design: Utilizes high-performance transducers with a frequency range from 1 to 10MHz to accommodate various material types.
  • High-Performance Signal Processing: Powered by 120MHz FPGA timing for accuracy and a 150V square wave pulser for strong signal penetration.
  • Field-Ready Display: Features a multi-function 4.5-digit LCD with a stability bar graph, rated for operation in temperatures as low as -22°F (-30°C).
  • Adjustable Velocity Control: Offers keypad-adjustable sound velocity from 305 to 18,542 m/sec to match the specific properties of the test material.
  • Ruggedized Construction: Built with a gasket-sealed extruded aluminum body and nickel-plated end caps for industrial durability.
  • Sealed Membrane Keypad: Designed to resist water and petroleum products, ensuring long-term reliability in oily or wet environments.
  • Selectable Units and Resolution: Supports seamless switching between English and Metric units with a high resolution of 0.001 inches (0.01 mm).
  • Extended Operational Runtime: Typically provides 45 hours of use on alkaline batteries, supported by an automatic low-battery shutoff.
  • Traceable Standards: Every unit includes a factory calibration traceable to NIST and MIL-STD-45662A, backed by a 5-year limited warranty.

ZX1 vs ZX2 Model Selection

Technical buyers can select between two configurations based on their material variety and setup requirements:

  • ZX1 Thickness Gauge: Positioned as the standard model for users who typically measure materials with a single known sound velocity. It allows for manual velocity adjustment directly on the keypad and serves as the replacement for the ZX-1.
  • ZX2 Thickness Gauge: Designed for operators who regularly switch between several common materials. It adds a selectable material list and 8 factory presets for faster setup, replacing the ZX-2.

ZX2 Factory Velocity Presets:

MaterialVelocity (in/μs)Velocity (m/sec)
Steel 4340.23305918
Stainless 303.22305664
Aluminum 2024.25106375
Cast Iron.18004572
Plexiglass.10602692
PVC.09402388
Polystyrene.09202337
Polyurethane.07001778
Custom 1 & 2ProgrammableProgrammable

Measurement, Velocity, and Calibration Workflow

The ZX1 / ZX2 series streamlines the Pulse-Echo measurement cycle. Accuracy is dependent on matching the gauge’s sound velocity setting to the specific material under test. While the ZX1 requires manual entry of the velocity, the ZX2 allows the user to simply select the material from a pre-defined list. The instrument features a 200Hz Pulse Repetition Frequency (PRF) and a 10Hz display update rate, providing immediate feedback. Operators should monitor the stability bar graph during measurement to ensure the transducer is properly coupled and the reading is reliable.

Display, Housing, Power, and Field Use

Operational efficiency in the field is supported by the series’ rugged physical architecture. The 0.500-inch high digits on the LCD provide clarity in direct sunlight, while the selectable backlight (on/off/auto) supports use in dark or low-visibility areas. The aluminum case is gasket-sealed to protect internal electronics from dust and moisture. Powered by two AA batteries, the gauges support various chemistries including alkaline, NiCad, and lithium. For specialized applications, locking quick-disconnect LEMO connectors allow for easy replacement or swapping of the 4-foot transducer cable.

Physical Design and Keypad

FeatureSpecification
Case MaterialExtruded aluminum; nickel-plated end caps (Gasket sealed)
Dimensions2.5 × 5.17 × 1.24 in (63.5 × 131.3 × 31.5 mm)
Weight11 ounces (with batteries)
Operating Temp.-22 to 167°F (-30 to 75°C)
KeypadSealed membrane; 7-8 tactile-feedback keys

Measuring and Display

FeatureSpecification
Measuring Range0.025 to 36.00 inches / 0.63 to 914.4 mm
Resolution0.001 inches / 0.01 mm
Velocity Range0.0120 to 0.7300 in/μs / 305 to 18,542 m/sec
Display TypeMulti-function 7-segment 4.5 digit LCD
PRF / Update Rate200Hz / 10Hz
BacklightSelectable On / Off / Auto (Lo, Med, Hi brightness)

Transducer and Power

FeatureSpecification
Transducer TypeDual-element (Transmit and Receive)
Frequency Range1 to 10MHz
ConnectorsLocking quick-disconnect LEMO
Cable4-foot shielded cable
Power Supply2 × AA Batteries (Alkaline, NiCad, or Lithium)
Battery Life~45 hours (Alkaline) / ~23 hours (NiCad)

Certification and Warranty

  • Calibration: Factory calibration traceable to NIST and MIL-STD-45662A.
  • Warranty: 5-year limited warranty.
  • Replacement Note: ZX1 replaces ZX-1; ZX2 replaces ZX-2.

Experience the Qualitest advantage and see how we can elevate your testing and quality control processes.

Please contact us for pricing, check availability, or ask for additional information about:

Ultrasonic Thickness Gauge ZX1 / ZX2