Wave-Scan 3 ROBOTIC Orange Peel DOI Meter
Wave-Scan 3 ROBOTIC moves orange-peel and DOI control onto the production line with automated, contactless measurement from a robotic arm. LAN Ethernet, fast onboard processing, OEM scale support, and structure-spectrum analysis help standardize appearance checks without slowing line throughput.
Description
Applications
Features
Specifications
The Wave-Scan 3 ROBOTIC Orange Peel DOI Meter automates orange peel, Distinctness of Image (DOI), dullness, and surface structure measurement on high-gloss finishes. Mounted on a robotic arm, the compact sensor performs contactless scans directly within automated production workflows.
Measurements operate at a surface distance of 15 ± 2 mm and a perpendicular angle tolerance of ± 2°. Scan speeds from 50 to 150 mm/sec support controlled robotic movement. The system requires vibration-free operation to maintain measurement consistency.
High-speed computing hardware supports automated data acquisition, while LAN Ethernet and USB interfaces provide connectivity for production environments. Classical LW and SW scales, customizable scales, structure spectrum analysis, and smart-chart software support appearance evaluation and documentation.
The Wave-Scan 3 ROBOTIC supports automated appearance measurement where consistent positioning and repeatable robotic movement are required:
- Automated Production-Line Measurement: Performs contactless appearance scans directly within production workflows.
- Robotic Surface Inspection: Mounts to a robotic arm for repeatable measurement sequences across defined surface locations.
- Orange Peel Measurement: Quantifies surface waviness on high-gloss finishes within a du < 40 linear range.
- Distinctness of Image Evaluation: Measures DOI as an independent appearance parameter across different paint systems.
- Dullness Measurement: Evaluates dullness separately from the structural spectrum and DOI.
- Curved Surface Measurement: Supports finished surfaces with a curvature radius greater than 500 mm.
- Structure Spectrum Analysis: Separates surface appearance into du, Wa, Wb, Wc, Wd, and We wavelength ranges.
- Automated Data Documentation: Transfers measurement data through LAN Ethernet or USB for analysis with smart-chart software.
- Automated Contactless Measurement: Performs appearance measurements without physical contact with the evaluated surface.
- Robotic Arm Integration: Configured for mounting to a robotic system within automated inspection workflows.
- Controlled Measurement Distance: Operates at 15 ± 2 mm from the measured surface.
- Defined Angular Positioning: Requires perpendicular sensor positioning within ± 2°.
- Adjustable Scan Speed: Supports robotic scan speeds from 50 to 150 mm/sec.
- High-Gloss Measurement Range: Measures surfaces within a du < 40 linear range.
- Structure Spectrum Analysis: Evaluates du, Wa, Wb, Wc, Wd, and We structures from below 0.1 mm to 30 mm.
- Independent DOI and Dullness Measurement: Evaluates both parameters independently of the paint system.
- Flexible Appearance Scales: Supports classical LW and SW scales together with customizable scales.
- Selectable Scan Lengths: Provides 5 cm, 10 cm, and 20 cm measurement lengths.
- LAN Ethernet and USB Connectivity: Supports data communication within automated measurement environments.
- Compact Sensor Housing: A 1.2 lb sensor provides flexible mounting options on compatible robotic systems.
- Detachable Mount: Uses a removable mounting system compatible with its predecessor.
- External Power Supply: Operates from a 9 to 24 VDC external source with a maximum current of 0.75 A.
- smart-chart Software: Supports analysis, visualization, and documentation of collected appearance measurements.
Automated Robotic Appearance Measurement
The Wave-Scan 3 ROBOTIC replaces operator-guided scanning with controlled movement from a robotic system. The sensor can follow programmed measurement locations while maintaining defined distance, angle, and scan-speed parameters. This configuration supports repeatable appearance measurement across production sequences.
The sensor measures without contacting the surface. During operation, the robotic system must maintain a distance of 15 ± 2 mm. Sensor orientation must remain perpendicular to the measured surface within ± 2°.
Robotic movement must also remain vibration-free. Scan speeds can range from 50 to 150 mm/sec. These parameters establish the required positioning conditions for automated surface measurement.
Orange Peel, DOI, and Dullness Evaluation
High-gloss appearance can vary through surface waviness, image clarity, and fine optical texture. The Wave-Scan 3 ROBOTIC evaluates orange peel alongside DOI and dullness within a du < 40 linear range. Each parameter contributes separate information about the measured finish.
DOI and dullness measurements operate independently of the paint system. This supports comparable appearance evaluation across different coatings where the defined measurement conditions remain applicable. Classical LW and SW scales are available for established analysis methods.
Customizable scales provide an additional option for application-specific evaluation. Measurement results can therefore be organized according to the appearance parameters used within a particular quality workflow.
Structure Spectrum Analysis
The Wave-Scan 3 ROBOTIC separates surface waviness into multiple wavelength bands. Rather than reducing appearance to one overall value, the structure spectrum identifies variations across short and long spatial ranges.
- du: < 0.1 mm
- Wa: 0.1 to 0.3 mm
- Wb: 0.3 to 1 mm
- Wc: 1 to 3 mm
- Wd: 3 to 10 mm
- We: 10 to 30 mm
These spectrum values allow engineering and quality teams to compare how surface structures change between measurements. The resulting data can be reviewed alongside DOI and dullness values for a broader appearance assessment.
Scan Geometry and Measurement Requirements
Selectable scan lengths of 5 cm, 10 cm, and 20 cm support different measurement areas. Resolution remains 375 points/cm throughout the scan. The minimum specified sample size is 35 mm x 150 mm.
Curved surfaces require a radius greater than 500 mm. The robotic system must maintain the specified sensor distance and angular orientation while following the surface. Stable, vibration-free movement is required throughout measurement.
A laser diode and LED provide the optical measurement sources. Laser energy remains below 1 mW and is classified as Laser Class 1.
Robotic Integration and Mounting
The sensor’s compact dimensions and 1.2 lb weight support installation on robotic equipment. A detachable mount provides mechanical flexibility and remains compatible with the predecessor mounting system.
Robotic integration must account for sensor position, movement speed, and vibration. The specified 15 ± 2 mm surface distance and perpendicular ± 2° angle define the working geometry. Movement speed must remain between 50 and 150 mm/sec during scanning.
An external 9 to 24 VDC power supply supports fixed installation without battery management. Maximum current is specified at 0.75 A.
LAN Connectivity and Data Workflow
LAN Ethernet provides the primary network interface for integration into automated measurement environments. USB connectivity is also available for data communication. The high-speed computing platform processes measurement data during robotic scanning.
Collected results can be evaluated with smart-chart software. The software supports data analysis and documentation of appearance measurements, including structure spectrum, DOI, dullness, and related measurement results.
This network-based workflow differentiates the robotic system from operator-controlled portable measurement. Data acquisition can remain integrated with the automated measurement sequence rather than relying on manual instrument handling and docking.
Application and Measurement
| Item | Specification |
| Application | High-gloss surfaces, du < 40, linear range |
| Measurement Parameters | Orange peel, DOI, dullness, structure spectrum |
| Object Curvature | Radius > 500 mm |
| Scan Length | 5 / 10 / 20 cm |
| Resolution | 375 points/cm |
| Minimum Sample Size | 35 mm x 150 mm |
Structure Spectrum
| Parameter | Wavelength Range |
| du | < 0.1 mm |
| Wa | 0.1 to 0.3 mm |
| Wb | 0.3 to 1 mm |
| Wc | 1 to 3 mm |
| Wd | 3 to 10 mm |
| We | 10 to 30 mm |
Measurement Performance
| Item | Specification |
| Repeatability (Std. Dev.) | 4% or > 0.4 |
| Reproducibility (Std. Dev.) | 6% or > 0.6 |
Robotic Measurement Requirements
| Item | Specification |
| Distance to Surface | 15 ± 2 mm |
| Angle to Surface | Perpendicular ± 2° |
| Scan Speed | 50 to 150 mm/sec |
| Robotic Requirement | Vibration-free operation |
Optical System
| Item | Specification |
| Light Source | Laser diode, LED |
| Laser Energy | < 1 mW |
| Laser Classification | Laser Class 1 |
Interface and Power
| Item | Specification |
| Interface | LAN Ethernet and USB |
| Power Supply | External power supply, 9 to 24 VDC |
| Maximum Current | 0.75 A |
Physical and Environmental Specifications
| Item | Specification |
| Weight | 1.2 lb |
| Operating Temperature | 10 to 40 °C / 50 to 104 °F |
| Storage Temperature | 0 to 60 °C / 32 to 140 °F |
| Relative Humidity | Up to 85% at 35 °C / 95 °F, non-condensing |
| Dimensions (L x W x H) | 11.2 x 6 x 13.1 cm / 4.4 x 2.4 x 5.2 in |
Experience the Qualitest advantage and see how we can elevate your testing and quality control processes.
Please contact us for pricing, check availability, or ask for additional information about: